VDF650
User
Manual
Desc
ription
of
Function
Codes
-
173
-
Table
6
-
5
Functions
of
output
terminals
Value
Function
Description
0
No
output
The
terminal
has
no
function
.
1
AC
drive
running
When
the
AC
drive
is
running
and
has
output
frequency
(
can
be
zero
),
the
terminal
becomes
ON
.
2
Fault
output
(
stop
)
When
the
AC
drive
stops
due
to
a
fault
,
the
terminal
becomes
ON
.
3
Frequency
-
level
detection
FDT1
output
Refer
to
the
descriptions
of
P8
-
19
and
P8
-
20
.
4
Frequency
reached
Refer
to
the
descriptions
of
P8
-
21
.
5
Zero
-
speed
running
(
no
output
at
stop
)
If
the
AC
drive
runs
with
the
output
frequency
of
0
,
the
terminal
becomes
ON
.
If
the
AC
drive
is
in
the
stop
state
,
the
terminal
becomes
OFF
.
6
Motor
overload
pre
-
warning
The
AC
drive
judges
whether
the
motor
load
exceeds
the
overload
pre
-
warning
threshold
before
performing
the
protection
action
.
If
the
pre
-
warning
threshold
is
exceeded
,
the
terminal
becomes
ON
.
For
motor
overload
parameters
,
see
the
descriptions
of
P9
-
00
to
P9
-
02
.
7
AC
drive
overload
pre
-
warning
The
terminal
becomes
ON
10s
before
the
AC
drive
overload
protection
action
is
performed
.
8
Set
count
value
reached
The
terminal
becomes
ON
when
the
count
value
reaches
the
value
set
in
FB
-
08
.
9
Designated
count
value
reached
The
terminal
becomes
ON
when
the
count
value
reaches
the
value
set
in
FB
-
09
.
10
Length
reached
The
terminal
becomes
ON
when
the
detected
actual
length
exceeds
the
value
set
in
FB
-
05
.
11
PLC
cycle
complete
When
simple
PLC
completes
one
cycle
,
the
terminal
outputs
a
pulse
signal
with
width
of
250
ms
.
12
Accumulative
running
time
reached
If
the
accumulative
running
time
of
the
AC
drive
exceeds
the
time
set
in
P8
-
17
,
the
terminal
becomes
ON
.
13
Frequency
limited
If
the
set
frequency
exceeds
the
frequency
upper
limit
or
lower
limit
and
the
output
frequency
of
the
AC
drive
reaches
the
upper
limit
or
lower
limit
,
the
terminal
becomes
ON
.
14
Torque
limited
In
speed
control
mode
,
if
the
output
torque
reaches
the
torque
limit
,
the
AC
drive
enters
the
stall
protection
state
and
meanwhile
the
terminal
becomes
ON
.
15
Ready
for
RUN
If
the
AC
drive
main
circuit
and
control
circuit
become
stable
,
and
the
AC
drive
detects
no
fault
and
is
ready
for
RUN
,
the
terminal
becomes
ON
.
16
AI1
larger
than
AI2
When
the
input
of
AI1
is
larger
than
the
input
of
AI2
,
the
terminal
becomes
ON
.
17
Frequency
upper
limit
reached
If
the
running
frequency
reaches
the
upper
limit
,
the
terminal
becomes
ON
.
18
Frequency
lower
limit
reached
(
no
output
at
stop
)
If
the
running
frequency
reaches
the
lower
limit
,
the
terminal
becomes
ON
.
In
the
stop
state
,
the
terminal
becomes
OFF
.
Summary of Contents for VDF650 Series
Page 1: ...VDF650 Series High Performance AC Drive...
Page 9: ......
Page 10: ...1 Safety Information and Precautions...
Page 17: ...Safety Information and Precautions VDF650 User Manual 16...
Page 18: ...2 Product Information...
Page 29: ...Product Information VDF650 User Manual 28...
Page 30: ...3 Mechanical and Electrical Installation...
Page 46: ...4 Operation Display and Application Examples...
Page 79: ...Operation Display and Application Examples VDF650 User Manual 78...
Page 80: ...5 Function Code Table...
Page 136: ...6 Description of Function Codes...
Page 248: ...7 EMC...
Page 260: ...8 Selection and Dimensions...
Page 285: ...Selection and Dimensions VDF650 User Manual 284...
Page 286: ...9 Maintenance and Troubleshooting...