Operation
,
Display
and
Application
Examples
VDF650
User
Manual
-
68
-
4
.
8
.
11
Use
of
the
Counting
Function
The
count
value
needs
to
be
collected
by
the
DI
terminal
that
is
allocated
with
function
25
.
When the count value reaches PB
-
08
(
Set count value
),
the DO terminal allocated with
function
8
(
Set
count
value
reached
)
becomes
ON
.
Then
the
counter
stops
counting
.
When
the
count
value
reaches
PB
-
09
(
Designated
count
value
),
the
DO
terminal
allocated
with
function
9
(
Designated count
value reached
)
becomes ON
.
The counter
continues
to
count
until
"
Set
count
value
"
is
reached
.
Figure
4
-
29
Parameter
setting
in
the
counting
mode
P4
-
00 to P4
-
09
=
25
(
Counting
pulses input
)
P4
-
00 to P4
-
09
=
26
(
Counting reset
)
Counting
pulses
Counting
reset
U0
-
12
(
counting value
)
Pb
-
09
(
Designated
counting value
)
≥
P5
-
00 to P5
-
05
=
8
(
Designated
counting value reached
)
Reset
Clear
to 0
After the
designated
counting value is
reached
,
set
the DO
terminal to 1
.
≥
Pb
-
08
(
Set counting
value
)
P5
-
00 to P5
-
05
=
9
(
Set counting
value reached
)
Reset
After the
set counting
value is reached
,
set
the DO terminal to 1
.
Counting reset
input
Designated counting
value reached output
Set counting value
reached output
Counting
pulses input
U0
-
12
:
Counting value
Pb
-
09
=
11
U0
-
12
=
11
1 2 3
10 11 12
U0
-
12
=
0
19 20 21
Pb
-
08
=
20
U0
-
12
=
20
1 2
Note
• PB
-
09
(
Designated
count
value
)
must
not
be
greater
than
PB
-
08
(
Set
count
value
).
• DI5
must
be
used
when
the
pulse
frequency
is
high
.
• The
DO
terminal
that
is
allocated
with
function
9
(
Designated
count
value
reached
)
and
the
DO
terminal
that
is
allocated
with
function
8
(
Set
count
value
reached
)
must
not
be
the
same
.
• In
the
RUN
/
STOP
state
of
the
AC
drive
,
the
counter
will
not
stop
until
"
Set
count
value
"
is
reached
.
• The
count
value
is
retentive
at
power
failure
.
• An
automatic
stop
system
can
be
implemented
if
the
signal
output
by
the
DO
terminal
with
the
function
(
Count
value
reached
)
is
fed
back
to
the
DI
terminal
of
the
AC
drive
with
stop
function
.
Summary of Contents for VDF650 Series
Page 1: ...VDF650 Series High Performance AC Drive...
Page 9: ......
Page 10: ...1 Safety Information and Precautions...
Page 17: ...Safety Information and Precautions VDF650 User Manual 16...
Page 18: ...2 Product Information...
Page 29: ...Product Information VDF650 User Manual 28...
Page 30: ...3 Mechanical and Electrical Installation...
Page 46: ...4 Operation Display and Application Examples...
Page 79: ...Operation Display and Application Examples VDF650 User Manual 78...