VDF650
User
Manual
Desc
ription
of
Function
Codes
-
161
-
Group
P4
:
Input
Terminals
The
VDF650
provides
fve
DI
terminals
(
DI5
can
be
used
for
high
-
speed
pulse
input
)
and
two
analog
input
(
AI
)
terminals
.
The
optional
extension
card
provides
another
fve
DI
terminals
(
DI6
to
DI10
)
and
an
AI
terminal
(
AI3
).
Function
Code
Parameter
Name
Default
Remark
P4
-
00
DI1
function
selection
1
:
Forward
RUN
(
FWD
)
Standard
P4
-
01
DI2
function
selection
4
:
Forward
JOG
(
FJOG
)
Standard
P4
-
02
DI3
function
selection
9
:
Fault
reset
(
RESET
)
Standard
P4
-
03
DI4
function
selection
12
:
Multi
-
reference
terminal
1
Standard
P4
-
04
DI5
function
selection
13
:
Multi
-
reference
terminal
2
Standard
P4
-
05
DI6
function
selection
0
Extended
P4
-
06
DI7
function
selection
0
Extended
P4
-
07
DI8
function
selection
0
Extended
P4
-
08
DI9
function
selection
0
Extended
P4
-
09
DI10
function
selection
0
Extended
The
following
table
lists
the
functions
available
for
the
DI
terminals
.
Table
6
-
1
Functions
of
DI
terminals
Value
Function
Description
0
No
function
Set
0
for
reserved
terminals
to
avoid
malfunction
.
1
Forward
RUN
(
FWD
)
The
terminal
is
used
to
control
forward
or
reverse
RUN
of
the
AC
drive
.
2
Reverse
RUN
(
REV
)
3
Three
-
line
control
The
terminal
determines
three
-
line
control
of
the
AC
drive
.
For
details
,
see
the
description
of
P4
-
11
.
4
Forward
JOG
(
FJOG
)
FJOG
indicates
forward
JOG
running
,
while
RJOG
indicates
reverse
JOG
running
.
The
JOG
frequency
,
acceleration
time
and
deceleration
time
are
described
respectively
in
P8
-
00
,
P8
-
01
and
P8
-
02
.
5
Reverse
JOG
(
RJOG
)
6
Terminal
UP
If
the
frequency
is
determined
by
external
terminals
,
the
terminals
with
the
two
functions
are
used
as
increment
and
decrement
commands
for
frequency
modifcation
.
When
the
frequency
source
is
digital
setting
,
they
are
used
to
adjust
the
frequency
.
7
Terminal
DOWN
8
Coast
to
stop
The
AC
drive
blocks
its
output
,
the
motor
coasts
to
rest
and
is
not
controlled
by
the
AC
drive
.
It
is
the
same
as
coast
to
stop
described
in
P6
-
10
.
9
Fault
reset
(
RESET
)
The
terminal
is
used
for
fault
reset
function
,
the
same
as
the
function
of
RESET
key
on
the
operation
panel
.
Remote
fault
reset
is
implemented
by
this
function
.
Summary of Contents for VDF650 Series
Page 1: ...VDF650 Series High Performance AC Drive...
Page 9: ......
Page 10: ...1 Safety Information and Precautions...
Page 17: ...Safety Information and Precautions VDF650 User Manual 16...
Page 18: ...2 Product Information...
Page 29: ...Product Information VDF650 User Manual 28...
Page 30: ...3 Mechanical and Electrical Installation...
Page 46: ...4 Operation Display and Application Examples...
Page 79: ...Operation Display and Application Examples VDF650 User Manual 78...
Page 80: ...5 Function Code Table...
Page 136: ...6 Description of Function Codes...
Page 248: ...7 EMC...
Page 260: ...8 Selection and Dimensions...
Page 285: ...Selection and Dimensions VDF650 User Manual 284...
Page 286: ...9 Maintenance and Troubleshooting...