VDF650
User
Manual
Desc
ription
of
Function
Codes
-
149
-
Function
Code
Parameter
Name
Setting
Range
Default
P1
-
09
Mutual
inductive
reactance
(
asynchronous
motor
)
0
.
1
–
6553
.
5
mH
(
AC
drive
power
≤
55
kW
)
0
.
01
–-
655
.
35
mH
(
AC
drive
power
>
55
kW
)
Model
dependent
P1
-
10
No
-
load
current
(
asynchronous
motor
)
0
.
01
to
P1
-
03
(
AC
drive
power
≤
55
kW
)
0
.
1
to
P1
-
03
(
AC
drive
power
>
55
kW
)
Model
dependent
The
parameters
in
P1
-
06
to
F
-
10
are
asynchronous
motor
parameters
.
These parameters
are
unavailable
on
the
motor
nameplate
and
are
obtained
by
means
of
motor
auto
-
tuning
.
Only
P1
-
06 to
P1
-
08
can
be
obtained
through
static
motor
auto
-
tuning
.
Through complete
motor
auto
-
tuning
,
encoder phase
sequence
and
current
loop
PI
can
be obtained besides
the
parameters
in
P1
-
06
to
P1
-
10
.
Each
time
"
Rated
motor power
" (
P1
-
01
)
or
"
Rated
motor
voltage
" (
P1
-
02
)
is
changed
,
the
AC
drive automatically
restores values of P1
-
06
to P1
-
10 to
the parameter setting for the
common
standard
Y
series
asynchronous
motor
.
If
it
is
impossible to perform motor auto
-
tuning
onsite
,
manually input the
values of these
parameters
according
to
data
provided
by
the
motor
manufacturer
.
Function
Code
Parameter
Name
Setting
Range
Default
P1
-
16
Stator
resistance
(
synchronous
motor
)
0
.
001
–
65
.
535
Ω
(
AC
drive
power
≤
55
kW
)
0
.
0001
–
6
.
5535
Ω
(
AC
drive
power
>
55
kW
)
Model
dependent
P1
-
17
Shaft
D
inductance
(
synchronous
motor
)
0
.
01
–
655
.
35
mH
(
AC
drive
power
≤
55
kW
)
0
.
001
–
65
.
535
mH
(
AC
drive
power
>
55
kW
)
Model
dependent
P1
-
18
Shaft
Q
inductance
(
synchronous
motor
)
0
.
01
–
655
.
35
mH
(
AC
drive
power
≤
55
kW
)
0
.
001
–
65
.
535
mH
(
AC
drive
power
>
55
kW
)
Model
dependent
P1
-
20
Back
EMF
(
synchronous
motor
)
0
.
1
–
6553
.
5
V
Model
dependent
P1
-
16
to
F
-
20
are
synchronous
motor
parameters
.
These
parameters
are
unavailable
on
the
nameplate of
most
synchronous motors and
can be obtained
by means of
"
Synchronous
motor
no
-
load auto
-
tuning
".
Through
"
Synchronous motor with
-
load auto
-
tuning
",
only the
encoder
phase
sequence
and
installation
angle
can
be
obtained
.
Each
time
"
Rated
motor power
" (
P1
-
01
)
or
"
Rated
motor
voltage
" (
P1
-
02
)
is
changed
,
the
AC
drive
automatically
modifes
the
values
of
P1
-
16
to
P1
-
20
.
You
can
also
directly
set the parameters
based on
the
data
provided
by
the
synchronous
motor
manufacturer
.
Function
Code
Parameter
Name
Setting
Range
Default
P1
-
27
Encoder
pulses
per
revolution
1
–
65535
1024
This
parameter
is
used
to
set
the
pulses
per
revolution
(
PPR
)
of
ABZ
or
UVW
incremental
encoder
.
In
CLVC
mode
,
the
motor
cannot
run
properly
if
this
parameter
is
set
incorrectly
.
Summary of Contents for VDF650 Series
Page 1: ...VDF650 Series High Performance AC Drive...
Page 9: ......
Page 10: ...1 Safety Information and Precautions...
Page 17: ...Safety Information and Precautions VDF650 User Manual 16...
Page 18: ...2 Product Information...
Page 29: ...Product Information VDF650 User Manual 28...
Page 30: ...3 Mechanical and Electrical Installation...
Page 46: ...4 Operation Display and Application Examples...
Page 79: ...Operation Display and Application Examples VDF650 User Manual 78...
Page 80: ...5 Function Code Table...
Page 136: ...6 Description of Function Codes...
Page 248: ...7 EMC...
Page 260: ...8 Selection and Dimensions...
Page 285: ...Selection and Dimensions VDF650 User Manual 284...
Page 286: ...9 Maintenance and Troubleshooting...