20
NivoGuide® 8100 • Two-wire 4 … 20 mA/HART
5 Connecting to power supply
58878-EN-190215
5
1
2
+
( )
(-)
6 7 8
4...20mA
2
3
4
1
Fig. 11: Electronics and connection compartment - single chamber housing
1 Voltage supply, signal output
2 For display and adjustment module or interface adapter
3 For external display and adjustment unit
4 Ground terminal for connection of the cable screening
5.4 Wiring plan, double chamber housing
The following illustrations apply to the non-Ex as well as to the Ex-ia
version.
5 6 7 8
4...20mA
1
2
+
( )
(-)
2
1
1
Fig. 12: Electronics compartment - double chamber housing
1 Internal connection to the connection compartment
2 For display and adjustment module or interface adapter
Electronics and connec-
tion compartment
Electronics compartment