52
NivoGuide® 8100 • Two-wire 4 … 20 mA/HART
7 Diagnostics and servicing
58878-EN-190215
3. Cable: remove the pins
4. Cable: Pull the cable out of the gravity weight
5. Shorten the cable/rod with a cut-off wheel or metal saw at the
marking. Take note of the specifications in the following illustration
when shortening the cable.
6. Cable with gravity weight: Shift the cable according to the drawing
into the gravity weight
7. Cable with gravity weight: Fasten cable with the pins, torque 7 Nm
(5.16 lbf ft)
Cable with centering weight: Fasten cable with the pins, torque
7 Nm (5.16 lbf ft) and fix the clamping part on the centering
weight.
8. Enter new probe length and then carry out a fresh adjustment
(see "
Setup procedure, Carrying out min. adjustment - Carrying
out max. adjustment
").
1
1
2
2
A
B
45 mm (1.77")
100 mm (3.94")
25 mm (0.98")
50 mm (1.97")
Fig. 29: Shortening the cable probe
A Gravity weight - cable ø 4 mm
B Gravity weight - cable ø 2 mm
1 Threaded pins
2 Thread M8 for eye-bolt
7.6 How to proceed if a repair is necessary
If it is necessary to repair the instrument, please contact the agency
serving you.