13
8x11 Venting NG: Closed
8x11 Venting LP: Closed - 3/16” open
5x8 Venting NG: 3/16” - 1/4” open
5x8 Venting LP: 3/8” - 7/16” open
Important Note
- When using 5x8 venting the burner shutter setting greatly effects both the burner
and pilot flames. Opening the shutter too much will result in a blue transparent flame and unstable pilot.
Maintenance And Service
b
uRneR
s
hutteR
c
aP
a
Djustment
:
The U44 contains an adjustable shutter cap that can alter the amount of air the burner receives. This can
greatly affect the quality of the burn, especially when converting the gas type for the unit. Follow these
steps carefully to properly set the shutter cap:
1. Remove the burner assembly from the unit (see
M
aIntenance
anD
s
erVIce
- B
urner
a
sseMBly
r
eMoVal
on page 12).
2. At the back of the burner (where the burner
connects to the burner orifice), there is a
single philips head screw that should be
loosened. This will allow for adjustment of
the burner cap (see Figure 11).
3. Adjust the shutter forward following the
guidelines below. These are general settings
only and the shutter may require additional
adjustment (less/more) depending on the
exact setup of the appliance:
Figure 12: Component Backpack Removal
c
omPonent
b
ackPack
R
emovaL
:
The component backpack houses the valve,
IFC and fuses for the fireplace. It is located
on the back right side of the unit. To remove
the backpack and access the components,
remove the eight (8) T-20 screws around
the perimeter (see Figure 12).
Once installed, the components can be
accessed from inside the firebox. Refer
to
M
aIntenance
a
nD
s
erVIce
- c
oMPonent
a
ccess
a
fter
I
nstallatIon
on page 15 for
instructions on how to do so.
*Note: Ensure that the backpack is properly
supported while removing from the unit to
avoid possible damage and injury.
Figure 11: Burner Shutter Adjustment