39
Initial Installation
QUALIFIED INSTALLERS ONLY
5”
x
8” v
ent
t
eRmination
c
LeaRances
Required Vinyl
Siding Standoff for
all combustible
building finishes.
Refer to approved
5x8 parts table
30” (762mm)
Minimum
Soffit / Overhang
Clearance
Termination Guard / Heat Shield
required if installed in a location
where the Termination could be
contacted. Refer to approved
venting parts table.
Termination Heat
Deflector
required for all
5x8 installations
(supplied)
The following termination restrictions only apply to 5” x 8” venting configurations. These restrictions are in
addition to those previously stated in the
V
ent
t
erMInatIon
r
estrIctIons
section on page 37.
Figure 60: Additional Termination Restrictions for 5” x 8” Venting
WARNING
-This gas appliance must be direct vented and can’t be connected to a chimney flue serving
a separate solid-burning appliances.
-Venting terminals cannot be recessed into a wall or siding.