19
Maintenance And Service
Please refer to your American Gas Association guidelines which state: the sea level rated input of
Gas Designed Appliances installed at elevations above 2000 (610 m) feet is to be reduced 4% for each
1000 feet (305 m) above sea level. Refer also to local authorities or codes which have jurisdiction in
your area regarding the de-rate guidelines.
In Canada
: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high
altitude rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).
14. MAKE SURE that the conversion labels provided are installed on or close to the rating label to signify
that the unit has been converted to a different fuel type.
Initial Installation
QUALIFIED INSTALLERS ONLY
i
ntRoDuction
:
This section of the owner’s manual is for the use of qualified technicians only. There are several installation
safety guidelines that must be adhered to; please carefully read the safety precautions at the front of this
manual.
u
nit
i
nstaLL
P
RePaRation
:
There are four (4) nailing flanges to secure the unit to the framing, they are assembled flat from the
manufacturer (see Figure 26). Flip the nailing flanges up 180 degrees and secure in place using the T-20
srews above pre-installed in the cabinet. Bend the flanges 90 degrees making them flush with the cabinet
face (see Figure 27).
Figure 26: Nailing Flange Flat
Figure 27: Nailing Flange
Assembled
n
aiLing
F
Langes
:
Please review the following instructions carefully to ensure the unit is prepared properly before installation.