![Universal Laser Systems PLS3.60 Safety, Installation, Operation, And Basic Maintenance Manual Download Page 89](http://html1.mh-extra.com/html/universal-laser-systems/pls3-60/pls3-60_safety-installation-operation-and-basic-maintenance-manual_1058522089.webp)
ACCESSORIES
Section 8-13
5.
Open the front door of the laser system
and carefully slide the cutting table into
the laser system so that its body is
squarely pushed up against the engraving
table rulers on the top and the side of the
table. The rulers of the cutting table
should now overlap the rulers on the
engraving table.
6.
Slide the adjustable manifold squarely up
against the exhaust plenum and tighten
the four (4) screws on the side of the
cutting table. Be careful not to move the
cutting table while tightening the screws.
The objective is to have the cutting table fit
snugly up against the rulers of the
engraving table and the adjustable
manifold fit tightly against the exhaust
plenum.
7.
We now need to adjust the rulers of the
cutting table so that they match the
engraving field of the laser system. Using
the focus tool method (Section 9-17),
adjust the Z Axis and focus directly onto
the surface of the honeycomb.
8.
Loosen slightly, but do not remove, the
five (5) screws that hold down the rulers.
9.
Activate the red diode pointer by opening the top door. Position the focus carriage at (0,0). With the
red diode pointer still ON, slide the X-axis ruler so that its zero (0) point lines up with the red diode
pointer and tighten down the left side screw.
10.
Now position the red diode pointer at the (32,0) position for the PLS6.60 and PLS6.120D series
machines or (24,0) position for the PLS3.60 and PLS4.60 series machine. Adjust the right side of the
X-axis ruler until it is lined up with the diode. Tighten down the right side screw of the X-axis ruler.
Now tighten down the middle screw.
11.
Line up the right edge of the Y-axis ruler with the zero (0) line of the X-axis ruler and tighten down the
top screw of the Y-axis ruler.
12.
Finally, position the red diode pointer at the (0,18) position for the PLS6.60 and PLS6.120D series
machine or the (0,12) position for the PLS3.60 and PLS4.60 series machine. Align the bottom of the
Y-axis ruler with the red diode pointer and tighten down the bottom screw of the Y-axis ruler. The
cutting table is now installed but lens calibration is needed.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3
4
5
6
7
8
9
10
11
12
ENGRAVING TABLE
CUTTING TABLE
ADJUSTABLE MANIFOLD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3
4
5
6
7
8
9
10
11
12
ADJUSTABLE MANIFOLD
EXHAUST PLENUM
SCREWS
SCREWS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
1
2
3
4
5
6
7
8
9
10
11
12
1) POSITION DIODE HERE
2) THEN HERE
3) AND FINALLY HERE
X-AXIS RULER
Y-
A
X
IS
R
U
L
E
R
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3
4
5
6
7
8
9
10
11
12
SCREWS
SCREWS
Summary of Contents for PLS3.60
Page 8: ......
Page 20: ...SAFETY Section 1 12 ...
Page 21: ...Part 1 Initial Setup ...
Page 22: ......
Page 30: ...INSTALLATION Section 2 10 ...
Page 44: ...GRAPHICS SOFTWARE SETUP Section 3 14 ...
Page 58: ...MAKING A SAMPLE Section 5 4 ...
Page 59: ...Part 2 Laser System Essentials ...
Page 60: ......
Page 70: ...BASIC SYSTEM FEATURES Section 6 12 ...
Page 76: ...BASIC MAINTENANCE Section 7 6 ...
Page 77: ...Part 3 Accessories ...
Page 78: ......
Page 95: ...Part 4 Advanced User ...
Page 96: ......