CHAPTER 3: OPERATING INSTRUCTIONS
PHASEMASTER™ 6 DIRECT ENERGY WELDING CONTROL
3-8
990-083
Line Voltage Compensation Feature On
The PM6's Automatic Line Voltage Compensation Feature can be switched to ON using the following
procedure:
a Select [NO WELD].
b Select Schedule 0.
c Press [SAVE] and [
?
] at the same time.
d The PM6 should display:
L
C
O
n
Line Voltage Compensation Feature Off
The PM6's Automatic Line Voltage Compensation Feature can be switched to OFF using the following
procedure:
a Select [NO WELD].
b Select Schedule 0.
c Press [SAVE] and [
?
] at the same time.
d The PM6 should display:
L
C
O
F
F
Alarm Display
As an example of the Alarm Display, Emergency Stop can be simulated by placing a jumper between Pin 5 and Pin
6, 7, 8, or 9 on the External Inputs Connector located on the rear panel. The alarm should sound and the PM6
should display:
S
E
E
A
2
The graphic means "See Alarm 2 – Chapter 3, Section I." Alarm A2 is Emergency Stop. The audible alarm will
stop within 5 seconds. Remove the jumper to clear the alarm message.