Display is Flashing “E4”
Possible Causes

Possible Remedies: (Unplug stove first when possible)

The air inlet, burnpot, interior combustion air 

chambers, combustion blower, or exhaust pipe 

are blocked with ash or foreign material.

Follow all cleaning procedures in the maintenance section of the 

owner’s manual.

The Proof of Fire (POF) thermodisc has came 

unplugged

Check the (POF) thermodisc to see if the wires are connected 

properly.

The Proof of Fire (POF) thermodisc has 

malfunctioned.

Temporarily bypass the POF thermodisc by disconnecting the 

two wires and connecting them with a short piece of wire. Then 

plug the stove back up. If the stove comes on and works, you need 

to replace the POF thermodisc. This is for testing only. DO NOT 

LEAVE THE THERMODISC BYPASSED. Your blowers will never 

shut off and if the fire went out the auger will continue to feed 

pellets until the hopper is empty if you leave the POF thermodisc 

bypassed.

The hopper is out of Pellets.

Refill the hopper.

 The hopper safety switch has failed or hopper is 

open.

When operating the unit, be sure the hopper lid is closed so that 

the hopper safety switch will activate. Check the wires leading 

from the hopper safety switch to the control panel and auger 

motor for secure connections. Use a continuity tester to test the 

hopper safety switch; replace if necessary.

The auger shaft is jammed.

Start by emptying the hopper. Then remove the auger motor by 

removing the auger pin. Remove the auger shaft inspection plate 

in the hopper so that you can see the auger shaft. Gently lift the 

auger shaft straight up so that the end of the auger shaft comes 

up out of the bottom auger bushing. Next, remove the two nuts 

that hold the top auger biscuit in. Then rotate the bottom end of 

the auger shaft up towards you until you can lift the shaft out of 

the stove. After you have removed the shaft, inspect it for bent 

flights, burrs, or broken welds. Remove any foreign material that 

might have caused the jam. Also, check the auger tube for signs 

of damage such as burrs, rough spots, or grooves cut into the 

metal that could have caused a jam. 

The auger motor has failed.

Remove the auger motor from the auger shaft and try to run the 

unit. If the motor will turn the shaft is jammed on something. If 

the motor will not turn, the motor is bad.

TROUBLESHOOTING GUIDE

Summary of Contents for US5513-W

Page 1: ...IAPROPOSITION65WARNING This product can expose you to chemicals including carbon monoxide whichisknowntotheStateofCaliforniatocause cancer birth defects and or other reproductive harm For more informa...

Page 2: ...uel Burn Rate lowest setting 1 65 lbs hr 0 75 kg hr Pellet size may effect the actual rate of fuel feed and burn times Fuel feed rates may vary by as much as 20 Use PFI listed fuel for best results Bu...

Page 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Page 4: ...Pin Com Cable 2 Unpack the top mount controls and ensure that all wires are securely attached 3 Connect the factory installed 5 Pin Main Wiring Harness to the top right hand corner of the control pan...

Page 5: ...IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF O...

Page 6: ...Canada Floor protector must comply with CAN ULC standards Must extend 18 458mm forward and 8 204mm beyond each side of unit A Back to Stove U S A 1 26 mm CAN 8 204 mm B Side to Stove U S A 6 153 mm CA...

Page 7: ...hassis of the mobile home transportable building with 8 GA copper wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and...

Page 8: ...disassemble for cleaning and should be checked several times during the burning season Pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The in...

Page 9: ...nstallation be taller than 3ft 0 91m to get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe in...

Page 10: ...d or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an example of an installation using part number 860001 3 6 transition into 6...

Page 11: ...located on the front lower left hand corner of your heater ON OFF Pressing the ON button on the control panel will begin the start up sequence for the heater Fuel will begin to feed through the auger...

Page 12: ...educed performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could res...

Page 13: ...3 4 will give you a higher heat output above medium and the damper should be open for these settings If the door is opened while the stove is in operation it must be closed within 30 seconds or the s...

Page 14: ...MES EXCEPT WHEN REFILLING DO NOT OVERFILL HOPPER TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this s...

Page 15: ...e heat exchanger To access these clean outs you must remove both side panels The clean outs are secured to the firebox with 2 5 16 screws Remove the clean outs and vacuum out any accumulated ash This...

Page 16: ...ect the vent from the stove GLASS We recommend using a high quality glass cleaner Should a buildup of creosote or carbon accumulate you may wish to use 000 steel wool and water to clean the glass DO N...

Page 17: ...lowers annually Remove the exhaust blower from the exhaust duct and clean out the internal fan blades as part of your fall start up If you have indoor pets your power motors should be inspected monthl...

Page 18: ...he chimney venting for transportation of a transportable building The parts or materials to be employed for ember protectors and the minimum areas to be covered and their relation to the space heater...

Page 19: ...se the slide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the inter...

Page 20: ...ombustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If...

Page 21: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Page 22: ...ating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure con...

Page 23: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Page 24: ...e caused a jam Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and co...

Page 25: ...l Burnpot holes are blocked Remove the burnpot and thoroughly clean it Blockage in air intake pipe Visually inspect the air intake pipe that leads into the burnpot for foreign material Combustion blow...

Page 26: ...Microswitch 1 9 80631 PCBA Main 1 10 80709 Room Blower 1 11 88347 Gasket 2 12 80455 High Temp Snapdisc Air 1 13 80915 RTD Temperature Probe 1 Key Part Description Qty 14 80872 Exhaust Blower 1 15 808...

Page 27: ...2023 United States Stove Company 27 CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM...

Page 28: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Page 29: ...____________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ______________________...

Page 30: ...2023 United States Stove Company 27 CORRECT FAUX Assurez vous que les fils sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr SCH MA DE C BLAGE...

Page 31: ...de couvercle de nettoyage 2 7 80913 Circuit imprim Wi Fi 1 8 80491 Micro interrupteur 1 9 80631 PCBA principal 1 10 80709 Ventilateur de chambre 1 11 88347 Joint 2 12 80455 Air Snapdisc haute temp rat...

Page 32: ...rents bois ont des caract ristiques diff rentes lorsqu ils sont br l s L interrupteur de surchauffe se d clenche tout le temps Causes possibles Solutions possibles D branchez le po le avant toute chos...

Page 33: ...de l arbre de la tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bloqu e Commencez par...

Page 34: ...e tableau de commande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la valeur nominale v r...

Page 35: ...rm pour permettre l interrupteur de s curit de la tr mie de s activer V rifiez le branchement des fils qui partent de l interrupteur de s curit de la tr mie jusqu au tableau de commande et au moteur d...

Page 36: ...Retirez ensuite le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintenant retirer le suppo...

Page 37: ...Panne du ventilateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilateur de combustion Ce...

Page 38: ...nviron 1 4 po apr s que votre po le se soit refroidi Red marrez votre po le Si votre cran affiche nouveau E1 fermez la glissi re de 1 4 po et recommencez Le ventilateur de convection surchauffe et d c...

Page 39: ...ons du fabricant de la chemin e pour le d montage de la chemin e ventilation pour le transport d un b timent transportable Les pi ces ou mat riaux utiliser pour les protecteurs de braises et les surfa...

Page 40: ...agr La porte de cet appareil utilise un joint 5 8 po corde de diam tre MOTEURS DES VENTILATEURS Nettoyez tous les ans les orifices d a ration des moteurs des ventilateurs d vacuation et de distributio...

Page 41: ...accumulation de cr osote ou de carbone s accumule vous pouvez utiliser de la laine d acier et de l eau pour nettoyer le verre N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsqu...

Page 42: ...re po le Le po le devra s teindre et s teindre compl tement avant que vous puissiez red marrer le po le CHAMBRES INT RIEURES Graver Pot P riodiquement enlever et nettoyer le pot de combustion et la zo...

Page 43: ...REMPLISSAGE NE REMPLISSEZ PAS TROP LA TR MIE AVERTISSEMENT LA TR MIE ET LE COUVERCLE DU PO LE SONT CHAUDS PENDANT LE FONCTIONNEMENT VOUS DEVEZ TOUJOURS PROT GER VOS MAINS LORS DU REMPLISSAGE DU PO LE...

Page 44: ...ustion lev e votre po le doit tre r gl sur le r glage 5 avec le registre compl tement ouvert Pour obtenir une combustion moyenne votre po le doit tre r gl sur le r glage 1 avec le registre compl temen...

Page 45: ...Institute densit minimale de 40 lb par pied cube diam tre de 1 4 5 16 moins de 8 200 BTU lb humidit inf rieure 8 en poids cendres inf rieure 1 en poids et sel inf rieur 300 parties par million Les gra...

Page 46: ...nt en appuyant sur le s bouton s appropri s du tableau de commande qui se trouve dans le coin inf rieur gauche l avant de l appareil ALLUMAGE EXTINCTION L appui sur le bouton ON du tableau de commande...

Page 47: ...qualifi avant de proc der l installation de votre po le granul s 2 Vous trouverez ci dessous des exemples d installations utilisant le num ro de pi ce 860001 transition de 3 6 pouces vers un tuyau de...

Page 48: ...recommand que la sortie de l installation se trouve plus de 3 pi 0 91 m pour chapper la ligne de cong re Cette m me installation peut tre utilis e si le po le se trouve sous le niveau du sol en ajout...

Page 49: ...LLATION DE L EVACUATION POUR POELE A GRANULES L installation doit comprendre un T de nettoyage pour permettre la collecte des cendres volantes et le nettoyage p riodique du syst me d vacuation des fum...

Page 50: ...sorties ext rieures doivent tre r install es et refix es Une prise d air ext rieur est obligatoire pour l installation dans une maisons mobiles b timents portatif Consultez la section Admission d air...

Page 51: ...le conform ment aux d gagements indiqu s ci dessous Pour des raisons de s curit veuillez respecter les d gagements et restrictions d installation Toute r duction du jeu aux combustibles ne peut tre ef...

Page 52: ...LA COMBUSTION DU COMBUSTIBLE G N RE DU MONOXYDE DE CARBONE QUI PEUT S AV RER DANGEREUX POUR LA SANT EN L ABSENCE D UNE VENTILATION APPROPRI E ATTENTION UN D TECTEUR DE FUM E FONCTIONNEL DOIT TRE INST...

Page 53: ...ches 2 D ballez les commandes mont es sur le dessus et assurez vous que tous les fils sont solidement fix s 3 Connectez le faisceau de c blage principal 5 broches install en usine au coin sup rieur dr...

Page 54: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Page 55: ...l Agence am ricaine de protection de l environnement 2020 pour les appareils de chauffage au bois vendus apr s le 15 mai 2020 Dans des conditions de test sp cifiques il a t d montr que cet appareil d...

Page 56: ...AIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entra ner d...

Reviews: