© 2023 United States Stove Company
11
OPERATION INSTRUCTIONS
NEVER OPERATE THIS PRODUCT WHILE UNATTENDED
HOW YOUR HEATER WORKS
Your pellet heater operates on a timer based auger fuel
feed system, that is controlled by a digital circuit board.
The fuel is delivered from the auger into a burn pot, which
is the vessel where the combustion process takes place.
Based upon the heat ranges (1-5), the heater will feed the
appropriate amount of fuel to reach a set temperature
range. Note that the amount of heat produced by the
heater is proportional to the rate of the fuel that is burned.
Your heater is equipped with an automatic ignition
system that should ignite the fuel within 5-10 minutes
from pressing the ON button. As pellets fall into the burn
pot and ignite, outside air is drawn in to feed the fire by a
combustion blower. The post combustion gases are then
pulled through the heat exchanger as they are traveling
out the exhaust. As the heater warms up, room air is
circulated around the heat exchanger by means of a room
air blower, distributing warm air into the room. Because
a forced draft pressure is required for the combustion
process inside your heater, it is extremely important
that the exhaust system be properly maintained. And,
that when operating your heater, you make sure that the
viewing and combustion doors are properly closed and/
or sealed.
CONTROL PANEL OVERVIEW
Turning the heater ON/OFF, as well as adjustments for
the fuel feed rate is performed by pressing the appropriate
button(s) on the control panel which is located on the
front, lower left-hand corner of your heater.
ON/OFF
• Pressing the “ON” button on the control panel will begin
the start-up sequence for the heater. Fuel will begin to
feed through the auger feed system then ignite after
approx. 5 minutes.
• Pressing the “OFF” button on the control panel will
cause the heater to enter its shut-down sequence. The
fuel feed system will stop pulling fuel from the hopper
and, once the fire goes out and the heater cools down,
the fans will stop running.
HEAT RANGE
• Pressing the “Heat Range” arrows, up or down, will
adjust the amount of fuel being delivered to the burn
pot.
• The exhaust blower will start. Note that this appliance
pulses the exhaust blower in order to achieve the
proper air to fuel ratio, and to also aid in the cleaning of
the burn pot.
• Once the heater reaches a set temperature, the room
fan will come on.
CONFIGURE
• Press the “Configure” button to begin pairing the unit
to your phone.
DISPLAY
• Pressing the “Display” button toggles the display
between the heat range and the room temperature.
MODE
• Use the “Mode” button to switch between manual
mode and thermostat mode.
HOW TO ADJUST THE FUEL ADJUSTER
It is a common occurrence in the pellet industry for the
average pellet size to vary. Due to the varying sizes of
pellets, this appliance is equipped with a fuel adjuster to
adjust the amount of fuel allowed to pass into the auger
assembly. The fuel adjuster is located inside the hopper.
Note: The factory default setting for this is full open. To
decrease the flow of pellets, move the fuel adjuster down.
1. Turn off and unplug the appliance.
2. Loosen the two wing-nuts.
3. Adjust up to increase, or down to reduce the fuel
usage based on the size of the pellets.
4. Tighten the two wing-nuts.