MAINTENANCE

CAUTION:

•  FAILURE TO CLEAN AND MAINTAIN THIS 

UNIT AS INDICATED CAN RESULT IN POOR 

PERFORMANCE, SAFETY HAZARDS, FIRE, AND 

EVEN DEATH. 

•  NEVER PERFORM ANY INSPECTIONS, 

CLEANING, OR MAINTENANCE ON A HOT 

STOVE.

•  DISCONNECT THE POWER CORD BEFORE 

PERFORMING ANY MAINTENANCE! NOTE: 

TURNING THE ON/OFF SWITCH TO ”OFF” 

DOES NOT DISCONNECT ALL POWER TO THE 

ELECTRICAL COMPONENTS OF THE STOVE.

•  DO NOT OPERATE STOVE WITH BROKEN GLASS, 

LEAKAGE OF FLUE GAS MAY RESULT.

CREOSOTE FORMATION, INSPECTION, & 

REMOVAL

CAUTION:

THE EXHAUST SYSTEM SHOULD BE CHECKED 

MONTHLY DURING THE BURNING SEASON FOR 

ANY BUILD-UP OF SOOT OR CREOSOTE.

When any wood is burned slowly, it produces tar and 

other organic vapors, which combine with expelled 

moisture to form creosote. The creosote vapors condense 

in the relatively cool chimney flue or a newly started 

fire or from a slow-burning fire. As a result, creosote 

residue accumulates on the flue lining. When ignited, this 

creosote makes an extremely hot fire, which may damage 

the chimney or even destroy the house. Despite their high 

efficiency, pellet stoves can accumulate creosote under 

certain conditions. The chimney connector and chimney 

should be inspected by a qualified person annually or per 

ton of pellets to determine if a creosote or fly ash build-

up has occurred. If creosote has accumulated, it should 

be removed to reduce the risk of a chimney fire. Inspect 

the system at the stove connection and at the chimney 

top. Cooler surfaces tend to build creosote deposits 

quicker, so it is important to check the chimney from 

the top as well as from the bottom. The creosote should 

be removed with a brush specifically designed for the 

type of chimney in use. A qualified chimney sweep can 

perform this service. It is also recommended that before 

each heating season the entire system be professionally 

inspected, cleaned and, if necessary, repaired. To clean 

the chimney, disconnect the vent from the stove.

GLASS

We recommend using a high quality glass cleaner. Should 

a buildup of creosote or carbon accumulate, you may wish 

to use 000 steel wool and water to clean the glass. DO 

NOT use abrasive cleaners. DO NOT perform the cleaning 

while the glass is HOT. Do not attempt to operate the unit 

with broken glass. Replacement glass may be purchased 

from your U.S. Stove dealer. If glass is broken, follow 

these removal procedures:
1.  Remove the four (8) screws and glass retainers. 
2.  While wearing leather gloves (or any other gloves 

suitable for handling broken glass), carefully remove 

any loose pieces of glass from the door frame. Dispose 

of all broken glass properly. ONLY high temperature 

ceramic glass of the correct size and thickness may 

be used. DO NOT substitute alternative materials for 

the glass. Contact your authorized dealer to obtain 

this glass. 

3.  Re-install the new glass by re-attaching the retainers 

and screws, be careful not to over tighten the screws 

for this could damage the glass.

DO NOT abuse the door glass by striking, slamming, or 

similar trauma. Do not operate the stove with the glass 

removed, cracked, or broken.

FLY ASH

This accumulates in the horizontal portion of an exhaust 

run. Though non-combustible, it may impede the normal 

exhaust flow. It should therefore be periodically removed.

ASH REMOVAL & DISPOSAL

CAUTION:

ALLOW THE STOVE TO COOL BEFORE PERFORMING 

ANY MAINTENANCE OR CLEANING. ASHES 

MUST BE DISPOSED IN A METAL CONTAINER 

WITH A TIGHT FITTING LID. THE CLOSED 

CONTAINER OF ASHES SHOULD BE PLACED ON 

A NON-COMBUSTIBLE SURFACE OR ON THE 

GROUND, WELL AWAY FROM ALL COMBUSTIBLE 

MATERIALS, PENDING FINAL DISPOSAL.

Remove the ashes periodically to avoid unnecessary ash 

build up. Remove ashes when unit has cooled. Ashes 

should be placed in a metal container with a tight fitting 

lid. The closed container of ashes should be placed on a 

noncombustible floor or on the ground, well away from 

all combustible materials, pending final disposal. If 

the ashes are disposed of by burial in soil or otherwise 

locally dispersed, they should be retained in the closed 

NEVER OPERATE THIS PRODUCT WHILE UNATTENDED

Summary of Contents for US5513-W

Page 1: ...IAPROPOSITION65WARNING This product can expose you to chemicals including carbon monoxide whichisknowntotheStateofCaliforniatocause cancer birth defects and or other reproductive harm For more informa...

Page 2: ...uel Burn Rate lowest setting 1 65 lbs hr 0 75 kg hr Pellet size may effect the actual rate of fuel feed and burn times Fuel feed rates may vary by as much as 20 Use PFI listed fuel for best results Bu...

Page 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Page 4: ...Pin Com Cable 2 Unpack the top mount controls and ensure that all wires are securely attached 3 Connect the factory installed 5 Pin Main Wiring Harness to the top right hand corner of the control pan...

Page 5: ...IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF O...

Page 6: ...Canada Floor protector must comply with CAN ULC standards Must extend 18 458mm forward and 8 204mm beyond each side of unit A Back to Stove U S A 1 26 mm CAN 8 204 mm B Side to Stove U S A 6 153 mm CA...

Page 7: ...hassis of the mobile home transportable building with 8 GA copper wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and...

Page 8: ...disassemble for cleaning and should be checked several times during the burning season Pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The in...

Page 9: ...nstallation be taller than 3ft 0 91m to get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe in...

Page 10: ...d or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an example of an installation using part number 860001 3 6 transition into 6...

Page 11: ...located on the front lower left hand corner of your heater ON OFF Pressing the ON button on the control panel will begin the start up sequence for the heater Fuel will begin to feed through the auger...

Page 12: ...educed performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could res...

Page 13: ...3 4 will give you a higher heat output above medium and the damper should be open for these settings If the door is opened while the stove is in operation it must be closed within 30 seconds or the s...

Page 14: ...MES EXCEPT WHEN REFILLING DO NOT OVERFILL HOPPER TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this s...

Page 15: ...e heat exchanger To access these clean outs you must remove both side panels The clean outs are secured to the firebox with 2 5 16 screws Remove the clean outs and vacuum out any accumulated ash This...

Page 16: ...ect the vent from the stove GLASS We recommend using a high quality glass cleaner Should a buildup of creosote or carbon accumulate you may wish to use 000 steel wool and water to clean the glass DO N...

Page 17: ...lowers annually Remove the exhaust blower from the exhaust duct and clean out the internal fan blades as part of your fall start up If you have indoor pets your power motors should be inspected monthl...

Page 18: ...he chimney venting for transportation of a transportable building The parts or materials to be employed for ember protectors and the minimum areas to be covered and their relation to the space heater...

Page 19: ...se the slide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the inter...

Page 20: ...ombustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If...

Page 21: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Page 22: ...ating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure con...

Page 23: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Page 24: ...e caused a jam Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and co...

Page 25: ...l Burnpot holes are blocked Remove the burnpot and thoroughly clean it Blockage in air intake pipe Visually inspect the air intake pipe that leads into the burnpot for foreign material Combustion blow...

Page 26: ...Microswitch 1 9 80631 PCBA Main 1 10 80709 Room Blower 1 11 88347 Gasket 2 12 80455 High Temp Snapdisc Air 1 13 80915 RTD Temperature Probe 1 Key Part Description Qty 14 80872 Exhaust Blower 1 15 808...

Page 27: ...2023 United States Stove Company 27 CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM...

Page 28: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Page 29: ...____________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ______________________...

Page 30: ...2023 United States Stove Company 27 CORRECT FAUX Assurez vous que les fils sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr SCH MA DE C BLAGE...

Page 31: ...de couvercle de nettoyage 2 7 80913 Circuit imprim Wi Fi 1 8 80491 Micro interrupteur 1 9 80631 PCBA principal 1 10 80709 Ventilateur de chambre 1 11 88347 Joint 2 12 80455 Air Snapdisc haute temp rat...

Page 32: ...rents bois ont des caract ristiques diff rentes lorsqu ils sont br l s L interrupteur de surchauffe se d clenche tout le temps Causes possibles Solutions possibles D branchez le po le avant toute chos...

Page 33: ...de l arbre de la tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bloqu e Commencez par...

Page 34: ...e tableau de commande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la valeur nominale v r...

Page 35: ...rm pour permettre l interrupteur de s curit de la tr mie de s activer V rifiez le branchement des fils qui partent de l interrupteur de s curit de la tr mie jusqu au tableau de commande et au moteur d...

Page 36: ...Retirez ensuite le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintenant retirer le suppo...

Page 37: ...Panne du ventilateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilateur de combustion Ce...

Page 38: ...nviron 1 4 po apr s que votre po le se soit refroidi Red marrez votre po le Si votre cran affiche nouveau E1 fermez la glissi re de 1 4 po et recommencez Le ventilateur de convection surchauffe et d c...

Page 39: ...ons du fabricant de la chemin e pour le d montage de la chemin e ventilation pour le transport d un b timent transportable Les pi ces ou mat riaux utiliser pour les protecteurs de braises et les surfa...

Page 40: ...agr La porte de cet appareil utilise un joint 5 8 po corde de diam tre MOTEURS DES VENTILATEURS Nettoyez tous les ans les orifices d a ration des moteurs des ventilateurs d vacuation et de distributio...

Page 41: ...accumulation de cr osote ou de carbone s accumule vous pouvez utiliser de la laine d acier et de l eau pour nettoyer le verre N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsqu...

Page 42: ...re po le Le po le devra s teindre et s teindre compl tement avant que vous puissiez red marrer le po le CHAMBRES INT RIEURES Graver Pot P riodiquement enlever et nettoyer le pot de combustion et la zo...

Page 43: ...REMPLISSAGE NE REMPLISSEZ PAS TROP LA TR MIE AVERTISSEMENT LA TR MIE ET LE COUVERCLE DU PO LE SONT CHAUDS PENDANT LE FONCTIONNEMENT VOUS DEVEZ TOUJOURS PROT GER VOS MAINS LORS DU REMPLISSAGE DU PO LE...

Page 44: ...ustion lev e votre po le doit tre r gl sur le r glage 5 avec le registre compl tement ouvert Pour obtenir une combustion moyenne votre po le doit tre r gl sur le r glage 1 avec le registre compl temen...

Page 45: ...Institute densit minimale de 40 lb par pied cube diam tre de 1 4 5 16 moins de 8 200 BTU lb humidit inf rieure 8 en poids cendres inf rieure 1 en poids et sel inf rieur 300 parties par million Les gra...

Page 46: ...nt en appuyant sur le s bouton s appropri s du tableau de commande qui se trouve dans le coin inf rieur gauche l avant de l appareil ALLUMAGE EXTINCTION L appui sur le bouton ON du tableau de commande...

Page 47: ...qualifi avant de proc der l installation de votre po le granul s 2 Vous trouverez ci dessous des exemples d installations utilisant le num ro de pi ce 860001 transition de 3 6 pouces vers un tuyau de...

Page 48: ...recommand que la sortie de l installation se trouve plus de 3 pi 0 91 m pour chapper la ligne de cong re Cette m me installation peut tre utilis e si le po le se trouve sous le niveau du sol en ajout...

Page 49: ...LLATION DE L EVACUATION POUR POELE A GRANULES L installation doit comprendre un T de nettoyage pour permettre la collecte des cendres volantes et le nettoyage p riodique du syst me d vacuation des fum...

Page 50: ...sorties ext rieures doivent tre r install es et refix es Une prise d air ext rieur est obligatoire pour l installation dans une maisons mobiles b timents portatif Consultez la section Admission d air...

Page 51: ...le conform ment aux d gagements indiqu s ci dessous Pour des raisons de s curit veuillez respecter les d gagements et restrictions d installation Toute r duction du jeu aux combustibles ne peut tre ef...

Page 52: ...LA COMBUSTION DU COMBUSTIBLE G N RE DU MONOXYDE DE CARBONE QUI PEUT S AV RER DANGEREUX POUR LA SANT EN L ABSENCE D UNE VENTILATION APPROPRI E ATTENTION UN D TECTEUR DE FUM E FONCTIONNEL DOIT TRE INST...

Page 53: ...ches 2 D ballez les commandes mont es sur le dessus et assurez vous que tous les fils sont solidement fix s 3 Connectez le faisceau de c blage principal 5 broches install en usine au coin sup rieur dr...

Page 54: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Page 55: ...l Agence am ricaine de protection de l environnement 2020 pour les appareils de chauffage au bois vendus apr s le 15 mai 2020 Dans des conditions de test sp cifiques il a t d montr que cet appareil d...

Page 56: ...AIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entra ner d...

Reviews: