18
© 2023 United States Stove Company
For Parts Assistance Call: 800-750-2723 Ext 5051 or Email: [email protected]
The information in this owner’s manual is specific to your unit. When ordering replacement parts the information in
this manual will help to ensure the correct items are ordered. Before contacting customer service write down the model
number and the serial number of this unit. That information can be found on the certification label attached to the
bottom of the hopper lid. Other information that may be needed would be the part number and part description of the
item(s) in question. Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once
this information has been gathered you can contact customer service by phone 1-800-750-2723 Ext 5051 or Email
Model Information
Model Number
Serial Number
INSTRUCTIONS SPECIFIC FOR CANADIAN
INSTALLATIONS
HOW TO ORDER REPAIR PARTS
Do not obstruct the space under the heater and do not
obstruct the combustion air openings.
Refer to the chimney manufacturer’s instructions for
disassembling the chimney/venting for transportation of
a transportable building.
The parts or materials to be employed for ember
protectors and the minimum areas to be covered and
their relation to the space heater, as well as the notice:
“In Canada, to comply with CSA B365, Installation Code
for Solid-Fuel-Burning Appliances and Equipment, any
combustible covering beneath the appliance and/or
within the area extending horizontally at least 450 mm
(18 in) beyond the appliance on any side equipped with a
door, and at least 200 mm (8 in) beyond the appliance on
other sides, shall be protected by a continuous, durable,
non-combustible pad that will provide ember protection.
The 450 mm (18 in) ember protection required on any
side with a door shall extend for the full width of the
appliance plus the 200 mm (8 in) required on each side
of the appliance without a door. Where an appliance is
installed less than 200 mm (8 in) from a wall, the ember
pad need only extend to the base of the wall. An ember
pad shall not be placed on top of a carpet unless the pad
is structurally supported to prevent displacement and
distortion.
If this appliance is installed in a transportable building,
removal of the chimney/venting is required for
transportation of the building.
DO NOT INSTALL IN AN ALCOVE
DO NOT INSTALL IN ANY FIREPLACE