© 2023 Breckwell
9
INSTALLATION
DO NOT connect the unit to a GFCI socket. Voltage
variations can lead to serious performance problems.
The Breckwell electrical system is designed for 120V AC
with no more than 5% variation. Breckwell cannot accept
responsibility for poor performance or damage due to
inadequate voltage. If connected to an older, two-prong
outlet, a separate ground wire should be run to a proper
ground (refer this to a qualified technician). Always route
the electrical cord so that it will not come in contact with any
hot part of the stove.
SPECIAL MOBILE HOME/TRANSPORTABLE
BUILDING REQUIREMENTS
WARNING! DO NOT INSTALL IN SLEEPING ROOM.
CAUTION! THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME/TRANSPORTABLE BUILDING FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
WHEN INSTALLED IN A MOBILE HOME/TRANSPORTABLE
BUILDING, THE STOVE MUST BE GROUNDED DIRECTLY
TO THE STEEL CHASSIS AND BOLTED TO THE FLOOR.
For installation in a mobile home/transportable building,
an outside source of combustion air must be used (see
“Combustion Air Supply”). This unit must be grounded to
the steel chassis with 8 Ga. copper wire using a serrated
or star washer to penetrate paint or protection coating to
ensure grounding. This unit must be securely fastened to the
floor of the mobile home/transportable building through the
two holes in the rear of the stove using 2-1/4” (58 mm) lag
bolts that are long enough to go through both a hearth pad,
if used, and the floor of the home. Refer to “Venting” for
proper exhaust configurations. When installing in a mobile
home/transportable building ensure that the vapor barrier
at the location where the chimney or other component
penetrates to the exterior of the structure. Never operate
with the firing doors open. A smoke detector should be
installed in the room where the heater is installed. The
smoke detector should be installed at least 10 feet away
from the heater to prevent accidentally setting the detector
off.
Summary of Contents for SP1000E
Page 2: ...Project 23 114 Model SP1000E Page 2 Revision History 6 14 2023 Original Issue...
Page 11: ...Project 23 114 Model SP1000E Page 11 Appliance Front Appliance Left...
Page 12: ...Project 23 114 Model SP1000E Page 12 Appliance Right Appliance Rear...
Page 14: ...Project 23 114 Model SP1000E Page 14 Pellet Fuel Analysis...
Page 17: ...Project 23 114 Model SP1000E Page 17 Sealed Unit...
Page 60: ......
Page 61: ......
Page 62: ......
Page 113: ...2023 Breckwell 27 ITEMS DEFINED...
Page 181: ......
Page 182: ......
Page 183: ......
Page 184: ......
Page 185: ......
Page 186: ......
Page 187: ......
Page 188: ......