Project # 23-114 Model: SP1000E
Page | 5
Introduction
US Stove of South Pittsburg, TN contracted with PFS-TECO to perform EPA certification
testing on SP1000E Pellet-Fired Room Heater. All testing was performed at PFS-
TECO’s
Portland Laboratory. Testing was performed by Mr. Sebastian Button.
Notes
•
Prior to start of testing, 50 hours of conditioning was performed by the
manufacturer at a medium heat setting, per ASTM E2779
•
Prior to start of testing, the dilution tunnel was cleaned with a steel brush.
•
A separate, independent sample train was utilized to determine 1
st
hour emissions.
•
A single test was performed in accordance with EPA ALT-146 burn rate settings:
o
1 Hour at Maximum Burn Setting
o
2 Hours at Medium Burn Setting (less than the mid-point of the high and low
rates)
o
3 Hours at Minimum Burn Setting