Run Data.xlsm
Manufacturer:
USSC
Model:
SP1000
Date:
05/19/23
Run:
1
Control #:
23-114
Test Duration:
180
Output Category:
Minimum
HHV Basis
LHV Basis
Overall Efficiency
71.3%
78.8%
Combustion Efficiency
99.5%
99.5%
Heat Transfer Efficiency
71.7%
79.2%
Output Rate (kJ/h)
6,936
6,580
(Btu/h)
Burn Rate (kg/h)
0.49
1.09
(lb/h)
Input (kJ/h)
9,726
9,226
(Btu/h)
Test Load Weight (dry kg)
1.48
3.27
dry lb
MC wet (%)
5.98
MC dry (%)
6.36
Particulate (g )
N/A
CO (g)
31
Test Duration (h)
3.00
Emissions
Particulate
CO
g/MJ Output
N/A
1.51
g/kg Dry Fuel
N/A
21.22
g/h
N/A
10.50
g/min
N/A
0.17
lb/MM Btu Output
N/A
3.52
Air/Fuel Ratio (A/F)
41.25
VERSION:
2.2
12/14/2009
Minimum Burn Rate Segment Efficiency Results
Test Results in Accordance with CSA B415.1-09
PFS-TECO
Page 6 of 35
Summary of Contents for SP1000E
Page 2: ...Project 23 114 Model SP1000E Page 2 Revision History 6 14 2023 Original Issue...
Page 11: ...Project 23 114 Model SP1000E Page 11 Appliance Front Appliance Left...
Page 12: ...Project 23 114 Model SP1000E Page 12 Appliance Right Appliance Rear...
Page 14: ...Project 23 114 Model SP1000E Page 14 Pellet Fuel Analysis...
Page 17: ...Project 23 114 Model SP1000E Page 17 Sealed Unit...
Page 60: ......
Page 61: ......
Page 62: ......
Page 113: ...2023 Breckwell 27 ITEMS DEFINED...
Page 181: ......
Page 182: ......
Page 183: ......
Page 184: ......
Page 185: ......
Page 186: ......
Page 187: ......
Page 188: ......