Project # 23-114 Model: SP1000E
Page | 16
Sampling Methods
ASTM E2515 was used in collecting particulate samples. The dilution tunnel is 12 inches
in diameter. All sampling conditions per ASTM E2515 were followed. No alternate
procedures were used.
Analytical Methods Description
All sample recovery and analysis procedures followed ASTM E2515 procedures. At the
end of each test run, filters, O-Rings and probes were removed from their housings,
dessicated for a minimum of 24 hours, and then weighed at 6 hour intervals to a
constant weight per ASTM E2515-11 Section 10.
Calibration, Quality Control and Assurances
Calibration procedures and results were conducted per EPA Method 28R, ASTM E2515-
11 and ASTM E2780-10. Test method quality control procedures (leak checks, volume
meter checks, stratification checks, proportionality results) followed the procedures
outlined.
Appliance Sealing and Storage
Upon completion of testing, the appliance was secured with metal strapping and the seal
below was applied, the appliance was then returned to
the manufacturer’s location at:
227 Industrial Park Road, South Pittsburg, TN 37380 for archival.
Sealing Label
Summary of Contents for SP1000E
Page 2: ...Project 23 114 Model SP1000E Page 2 Revision History 6 14 2023 Original Issue...
Page 11: ...Project 23 114 Model SP1000E Page 11 Appliance Front Appliance Left...
Page 12: ...Project 23 114 Model SP1000E Page 12 Appliance Right Appliance Rear...
Page 14: ...Project 23 114 Model SP1000E Page 14 Pellet Fuel Analysis...
Page 17: ...Project 23 114 Model SP1000E Page 17 Sealed Unit...
Page 60: ......
Page 61: ......
Page 62: ......
Page 113: ...2023 Breckwell 27 ITEMS DEFINED...
Page 181: ......
Page 182: ......
Page 183: ......
Page 184: ......
Page 185: ......
Page 186: ......
Page 187: ......
Page 188: ......