VersaPro Temperature Controller
Page 73
Copyright © 2013, United Process Controls Inc.
All rights to copy, reproduce and transmit are reserved
BLOCK 1
HEX
DEC
PARAMETER
DESCRIPTION
READ/WRITE
*For Programmable, write required output value
into DACV1, where DACV1 = 0 is minimum output
and
DACV1 = 4096 is maximum output.
BITS 4 – 7 SPARE
HIGH BYTE, ANALOG OUTPUT 2
BITS 8 – 12
0000 = N/A
0001 = Temperature
0010 = Linear Input A
0011 = Carbon value
0100 = Dewpoint value
0101 = Oxygen value
0110 = Redox value
0111 = Output Power
1000 = Control Output 1
1001 = Control Output 2
1010 = Linear Input B
1011 = Programmable*
*For Reference Number and Programmable , write
required output value into DACV2, where DACV2
= 0 is minimum output and
DACV2 = 4096 is maximum output.
BITS 13 – 15 SPARE
Special case: If Analog Output 1 = CONTROL
OUTPUT 1 and Analog Output 2 = CONTROL
OUTPUT 2 and the Control Mode is dual, then
Analog Output 1 is 4-20ma for 0 to +100% PO and
Analog Output 2 is 4-20ma for 0 to -100% PO.
19
25
AOUTOF1
ANALOG OUTPUT 1 OFFSET
Minimum source value that correlates to minimum
Analog Output of 4 mA. The source value is
based on the selection in ASRC lower byte
READ ONLY
1A
26
AOUTRN1
ANALOG OUTPUT 1 RANGE
Maximum source value that correlates to maximum
Analog Output of 20 mA. The source value is
based on the selection in ASRC lower byte where
READ ONLY
1B
27
AOUTOF2
ANALOG OUTPUT 2 OFFSET
Minimum source value that correlates to minimum
Analog Output of 4 mA. The source value is
based on the selection in ASRC upper byte
READ ONLY
1C
28
AOUTRN2
ANALOG OUTPUT 2 RANGE
Maximum source value that correlates to maximum
READ ONLY