7: Options
7-6
UPS338-01-00 PowerWAVE 8000-RI DPA User Manual Dated 5 April 2013
7.6
Modem/Ethernet card / PowerREPORTER™ management software
PowerREPORTER™ is a redundant remote monitoring and management service which is a part of the
Premium Power Protection Concept. It provides peace-of-mind protection, offering continuous (24/7/365)
watch over mission-critical facilities.
There are two different solution cards: ‘Modem/Ethernet’ or ‘Modem/GSM’ to connect the UPS to the outside
world.
Continuous monitoring is an affordable insurance policy to detect and warn before they become a crisis:
• Acquire key performance parameter and productivity information in real-time to empower you with the
details needed to better understand machine performance and faster troubleshoot downtime events.
• Early warning system, so problems can be addressed before they become a real threat to the load.
Professional experts, your virtual service technician onside.
• Total transparency of information and actions performed like Notification of all critical status changes,
Coordination of equipment service, Reporting of all alarms with priorities.
What are the Features?
• Redundant and secure communication
• Alarm acknowledgment
• Priority driven Management (with escalation)
Comprehensive Management System
• Reception and management of alarm calls from UPS
• Storage of UPS Data in a database exportable in a CSV-format for easy handling in Excel
• Unlimited number of UPS that can be managed
• User administration with passwords and permission-level
• Administration of Log file
• Data logging with statistical analysis and diagnostics, report
• Visualization of the UPS data
– Current status (“single” and “parallel” operation)
– Measured values for single or three phase
– Recording function including graphs with zooming capabilities for selected measured values
– Display of event log file
– Display of UPS Parameters
– Web Server functionality, for data access from any Web Browser
Figure 7.5 PowerREPORTER™ management software
M
M
O
O
D
D
E
E
M
M
UPS systems
1 ….1000
Alarm
Situation
Problem in
the System
Optional
Interface Card
Modem GSM
Modem
Net work int erface
(et hernet )
I
I
N
N
T
T
E
E
R
R
N
N
E
E
T
T
M
M
O
O
D
D
E
E
M
M
Communication
Interface (PLC’s)
1 ….10
Co mmunication
Interface (PLC’s)
I
I
N
N
T
T
E
E
R
R
N
N
E
E
T
T
Call back
SSL
Managem ent
Station
PowerREPORTER
Summary of Contents for PowerWAVE 8000DPA RI
Page 1: ...User Manual PowerWAVE 8000DPA RI Pioneering solutions for total power protection ...
Page 2: ...UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...
Page 4: ...UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...
Page 8: ... iv UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...
Page 10: ...1 Safety 1 2 UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...
Page 16: ...2 General Description 2 6 UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...
Page 42: ...3 Installation 3 26 UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...