PNG Configuration
A31003-G2100-S100-2-7620, 03/2014
16
PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
SHB_PNG07.fm
Alarm Configuration
Factory setting: No number
The factory setting for the "Alarm Number Basis" is "No number", that is, you must configure a
number here.
Recommendation for BGR 139 configuration
Configure the "Alarm Number Basis" in line with the PNEZ configuration.
7.2.1.2
PNEZ Basis (Number Configured)
The "PNEZ Basis" is the base number of the PNEZ with its different control ports (see Section
7.2.5, “Control Ports”) that are used for signalling and operating the PNG handset.
Changing this parameter is optional because after you enter the "Alarm Number Basis", the
"PNEZ Basis" and all control ports that are dependent on it are automatically calculated using
the following formula: "PNEZ Basis" = "Alarm Number Basis" + 10.
Example: enter the following as the "Alarm Number Basis": "52200". The "PNEZ Basis" is cal-
culated as 52210 and pre-configured.
If you want to change the "PNEZ Basis", enter a new number (maximum 32 digits).
The numbers of the PNEZ control port are derived from this "PNEZ Basis" as automatically pre-
configured numbers.
Please note:
changing and saving "PNEZ Basis" always affects all dependent configurations.
Dependent configurations are the following:
●
All control ports
Please note:
you must first define the "PNEZ Basis", then make individual changes to the
phone numbers of the control ports.
Factory setting: No number
The factory default for the "PNEZ Basis" is "No number", but the "PNEZ Basis" and the control
ports are automatically configured when the "Alarm Number Basis" is entered.
Recommendation for BGR 139 configuration
Configure the "PNEZ Basis" in line with the PNEZ configuration. Use the handset’s automatic
configuration function whenever possible.