SHB_PNG04.fm
A31003-G2100-S100-2-7620, 03/2014
PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
9
PNG-S in HiPath Cordless Office
4
PNG-S in HiPath Cordless Office
The handset works without a control centre when operating in HiPath Cordless Office. A PNEZ
is not available to a HiPath Cordless Office.
You can choose how to set the PNG parameters and configure the handset to suit your require-
ments.
Monitoring is activated directly by the handset.
The alarm functions are not tested. However, you can check the alarm function when monitor-
ing is active by triggering the relevant alarm event.
PNG-S alarm calls are routed to the alarm destination set.
In order to ensure that the alarm calls reach the alarm destination they are repeated until the
alarm call count has been reached or until alarm repetition has been interrupted manually on
the handset.
An alarm recall to confirm the alarm call (ending the alarm repeats and possibly the silent mo-
nitoring of the person sending the alarm) is only possible on HiPath 3000 versions which sup-
port CLIP transmission in the setup message. Bear this in mind when configuring the number
of alarm repetitions.
The required control ports must be set in the mobile phone for the alarm callback. See Section
7.2.5, “Control Ports”.
Monitoring is deactivated directly on the handset.
Restriction
Despite alarm repetitions, there is no guarantee that all alarm calls will reach the programmed
destination.
Configuration tip
To ensure that the PNG-S can start up without PNEZ, the "PNEZ Basis" parameter must be
deleted from the PNG configuration. See also Section 7.2.1.2, “PNEZ Basis (Number Config-
ured)” and Section 7.2.1.3, “PNEZ Basis (Number Deleted)”.
7
This type of operation does not conform to BGR 139.