PNG Configuration
A31003-G2100-S100-2-7620, 03/2014
30
PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
SHB_PNG07.fm
Alarm Configuration
7.2.3.3
Time Alarm
Activation of the time alarm is optional. The time alarm is activated if a timed prealarm is not
acknowledged within the preset period.
Table 7-12
Parameter setting for time alarm
7.2.3.4
Escape Alarm
Activation of the escape alarm is optional. The escape alarm is triggered when the sensors de-
tect an inadmissible sudden movement lasting for a defined and configurable period of time.
Table 7-13
Parameter setting for escape alarm
Parameter
Setting range
Factory setting
BGR 139
Activation
On/Off
Off
At least one autom.
alarm
Response time
1 min ... 120 min
30 min
<= 30 min
Prealarm time
0 s ... 30 s
15 s
5 s ... 15 s
Alarm Signal
On/Off
On
On
Alarm destination
32-digit number
Blank (see Section
7.2.1.1, “Alarm Num-
ber Basis”)
Align with PNEZ
Parameter
Setting range
Factory setting
BGR 139
Activation
On/Off
Off
At least one autom.
alarm
Response time
10 s ... 900 s
30 s
<= 30 s
Prealarm time
0 s ... 30 s
15 s
0 s ... 15 s
Alarm Signal
On/Off
On
On
Sensitivity level
Low/medium/high
Medium
If required
Alarm destination
32-digit number
Blank (see Section
7.2.1.1, “Alarm Num-
ber Basis”)