SHB_PNG07.fm
A31003-G2100-S100-2-7620, 03/2014
PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
21
PNG Configuration
Alarm Configuration
7.2.1.5
Repeat Alarm Time [sec]
The PNG-S automatically signals the alarm call at the alarm destination. Alarm calls are auto-
matically repeated to ensure reliable signalling.
This parameter can be used to set the time for the alarm repetitions. If you enter 4 s, for ex-
ample, the system initiates a 4-second alarm call and a 4 second break. This is followed by a
repeated alarm call and a pause.
The call and interval duration is s increased by one second after every alarm call.
Select a longer repeat alarm time for calls that break out into the public network. The call du-
ration must be long enough to reach the alarm destination. Make test calls if necessary.
You can communicate with the alarm destination throughout over the connection duration once
the alarm signal is off or manually deactivated (see Section 7.2.1.7, “Signal Off - manual”)
Example:
Figure 7-1
Call and interval duration
Table 7-4
Parameter setting for Repeat Alarm Time
Parameter
Setting range
Factory setting
BGR 139
Repeat Alarm Time
1 s ... 30 s
4 s
4 s
Call 1
Interval 1
4 s
4 s
Call 2
Interval 2
5 s
5 s
Call 3
Interval 3
6 s
6 s