PNG Configuration
A31003-G2100-S100-2-7620, 03/2014
24
PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
SHB_PNG07.fm
Alarm Configuration
7.2.1.8
Signal Off - autom.
This parameter controls whether the alarm/positioning tone will be automatically suppressed.
●
Signal Off - autom. = On
This configuration parameter suppresses the alarm/positioning tone in alarm mode while
the PNEZ performs an alarm recall to the PNG-S signalling the alarm. The PNEZ can use
the alarm recall feature to hear what is going on at the alarm location or speak with the
alerting party without this party operating the PNG-S.
The positioning tone is suppressed for the duration of the alarm recall.
Table 7-6
Parameter setting for Signal Off - autom.
7.2.1.9
Autom. alarms OFF
This parameter permits or prohibits the suspension or reactivation of automatic alarms when
the handset is in monitoring mode.
●
Autom. alarms OFF = No
All activated automatic alarms (non movement, man down, time and pull cord alarms,
forinstance) remain active while the handset is in monitoring mode.
●
Autom. alarms OFF = Off in charger
The activated automatic alarms are suspended when the handset is placed a charger. Pre-
alarms and alarms are no longer generated during this time. The alarms are reactivated
once the handset is removed from the charger. This does not apply to the deliberate alarm
or the technical fault warning.
The function is implemented locally on the handset. There is no communication with the
PNEZ. The PNG LED displays the new monitoring mode.
Parameter
Setting range
Factory setting
BGR 139
Signal Off - autom.
On/Off
On
On
(The PNEZ controls
the alarm recall and
its duration. The po-
sitioning tone is en-
abled once more in
the PNG-S after an
alarm recall.)
7
This type of operation does not conform to BGR 139.