Page 75
Version 3.3 / November 2016
Sub-menu
Description
Value
1.9.7.12.5 Photocell
Shows the state of the optic cup sensor. If the sensor is not
installed it always shows FULL
Empty
Full
1.9.7.12.6 Waste
Shows the reading of the liquid waste sensor
Empty
Full
1.9.7.12.7 Group
Shows espresso group position sensors’ readings
Open
Close
Out of position
Missing
1.9.7.12.8 Selector
Shows the readings of selector position sensors
0 position
i position
0 position error
Out of position
1.9.7.12.9
Cups dispenser
Shows the readings of cup dispenser sensor
Out of position
0 position
1.9.7.12.10
Stirrer / sugar
Shows the state of spoon dispenser
Out of position
0 position
1.9.7.12.11
Coffee waste full
Shows the readings of the coffee waste sensor
Out of position
0 position
1.9.7.12.12
Coffee waste number
Shows the readings of the current state of coffee waste meter
1.9.7.13 Debug
•
“Yes” – Machine debugging mode, with an option to log the
latest (past few hours of functioning) events to a USB flash
drive. It is normally used in case of system failures and
errors to log and transfer this data to the service center of
the supplier
No/Yes
1.9.7.14 Debug quantity
•
“Yes” – Machine debugging mode, with an option to log the
latest (past few hours of functioning) events to a USB flash
drive. It is normally used in case of system failures and
errors to log and transfer this data to the service centre of
the supplier
No/Yes
1.9.7.15 Test loop
Let’s you perform cyclical preparation of two drinks simultaneously to test the ma-
chine
1.9.7.15.1 Test sel 1
Enter number of first tested drink
1...16
1.9.7.15.2 Delay sel 1 s Enter the period of pause in seconds after the preparation of
drink 1
0...59
1.9.7.15.3 Delay sel 1 m Enter the period of pause in minutes after the preparation of
drink 1
0...59
1.9.7.15.4 Test sel 2
Enter number of second test drink
1...16
1.9.7.15.5 Delay sel 2 s Enter the period of pause in seconds after the preparation of
drink 2
0...59
1.9.7.15.6 Delay sel 2 m Enter the period of pause in minutes after the preparation of
drink 2
0...59
1.9.7.15.7
Number of tests
Enter number of test cycles
0...250
0 = infinite
1.9.7.15.8 Start test
Start cyclical test. To prematurely stop the test turn the machine
OFF and then switch it ON again
No/Yes
1.9.7.16 Keyboard test
Keyboard test – displays all pressed keys on the screen
All buttons on
the keyboard