43
Fault finding
5
FAULT FINDING
2
1
3
Code:
Description:
DHW sensor failure (SS)
Corrective action:
Check the sensor’s efficiency and/or its wiring
Code:
Description:
Mains supply < 190 Vac
Corrective action:
Corrective action: Check that the mains supply is
< 190Vac. If the mains supply is correct replace
the control board.
Code:
Description:
Insufficient gas pressure
Corrective action:
Check the pressure, if the pressure is correct
control the gas switch and/or its wiring.
Code:
Description:
Difference between the temperature of the CH
sensor (SR) and the temperature of the heating
return sensor (SRR) > 35°C.
Corrective action:
Examine the system.
Code:
Description:
Failure of the heating return sensor (SRR)
Corrective action:
Corrective action: Check the efficiency of the
sensor and/or its wiring
Code:
Description:
Bad water circulation
Corrective action:
Examine the system
Code:
Description:
Loss of flame signal during boiler operation
Corrective action:
Press the reset button on the control panel
Code:
Description:
No flame detected during the ignition phase
Corrective action:
Press the reset button on the control panel
Code:
Description:
Modulating fan failure
Corrective action:
Check the fan’s wiring
Code:
Description:
Modulating fan failure
Corrective action:
Check the fan’s wiring
Code:
Description:
Main heat exchanger frozen
Corrective action:
Carefully de-frost the exchanger
Code:
Description:
Water temperature too high detected by the CH
sensor (SR) (>95°C)
Corrective action:
Check adequate flow of water through boiler
Code:
Description:
Intervention of the overheat safety thermostat (TL)
Corrective action:
Press the reset key on the control panel
Code:
Description:
Heating sensor failure (SR)
Corrective action:
Check the sensor’s efficiency and/or wiring
The boiler is fitted with an integrated diagnostic readout whi-
ch, in case of malfunction, consents the immediate individua-
tion of the type of fault directly from the control panel display.
In the following fault finding table our purpose is to give some
technical information regarding the solutions to any problems
which could occur during boiler operation or commissioning of
the boiler.
When the fault signalling led (1) is illuminated, press the LI-
GHT BLUE key (2) to check the error code on the display (3).
5.1 - ERROR CODES