33
Instructions for the installer
3.16 -
PROGRAMMING OF THE OPERATING PARAMETERS
WARNING! THESE OPERATIONS ARE ACCESSIBLE ONLY TO TRAINED INSTALLERS AND SERVICE
ENGINEERS FOR INSPECTION AND EVENTUAL CHANGES OF THE PARAMETER SETTINGS
eBUS IDENTIFICATION CODE
By pressing the
YELLOW
key you gain
access
to the first
adjustable parameter
eBUS IDENTIFICATION CODE (SC)
.
Standard setting:
0
(Operation A)
By pressing the YELLOW key again the standard parameter
setting is displayed.
A
Z
Z
U
R
R
O
V
I
O
L
A
G
I
A
L
L
O
B
L
U
(Operation B)
By pressing the keys
+
(increase) or
–
(decrease) a number of
times the parameter can be changed.
(Operation C)
After setting the desired value pressing the
YELLOW
key stores
this new value in the memory.
A
Z
Z
U
R
R
O
V
I
O
L
A
G
I
A
L
L
O
B
L
U
A
Z
Z
U
R
R
O
V
I
O
L
A
G
I
A
L
L
O
B
L
U
A
Z
Z
U
R
R
O
V
I
O
L
A
G
I
A
L
L
O
B
L
U
BURNER MODULATION LEVEL IN IGNITION
Continue to change the parameters by pressing the
–
key
(decrease).
The successive parameter which can be changed is:
BURNER
MODULATION LEVEL IN IGNITION (IG)
Press down the
YELLOW
and
LIGHT BLUE
key
simultaneously to enter in the service menu
SE
, which will
appear on the display, and change the pre-set values of the
operating parameters.
A
Z
Z
U
R
R
O
V
I
O
L
A
G
I
A
L
L
O
B
L
U
Repeat the operations
A
-
B
-
C
for setting the desired value from
0
to
99
%.
Standard Natural Gas setting 70 %
Standard LPG setting 30%
PUMP OVERRUN
Continue to change the parameters by pressing the
–
key
(decrease).
The successive parameter which can be changed is:
PUMP
OVERRUN (Po).
A
Z
Z
U
R
R
O
V
I
O
L
A
G
I
A
L
L
O
B
L
U
Repeat the operations
A
-
B
-
C
for setting the desired value from
1
to
10
minutes.
Standard setting: 5 minutes
WARNING!
DO NOT CHANGE THE PARAMETER
A
Z
Z
U
R
R
O
V
I
O
L
A
G
I
A
L
L
O
B
L
U