39
Instructions for the installer
4.
TIMER/HEATING PROGRAM ADJUSTMENT
•
Open the heating controller’s panel cover and turn the ro-
tary knob in a clockwise direction until TIME PROGRAM
appears on the display.
A
s
si
st
e
n
z
a
D
a
ta
/O
ra
/F
e
ri
e
V
is
u
a
liz
z
a
zi
o
n
e
Ut
e
n
te
P
ro
g
rr
a
mma
T
e
mp
o
Te
c
n
ic
o
In
s
ta
lla
z
Ac
q
u
a
c
a
ld
a
Ci
rc
u
it
o
ri
s
c
a
ld
a
m
e
n
to
I
C
ir
c
ui
to
r
is
cal
da
m
e
nt
o
II
P
a
nn
el
li s
o
la
ri
4
3
2
1
1
2
1
2
1
2
®
Time PROGRam
- When the time has elapsed the cursor will position itself
on the CIRCL TIME level.
A
ssist
e
n
z
a
Da
ta
/O
ra
/F
e
ri
e
V
is
u
al
iz
z
a
z
ion
e
Ut
e
n
te
Pr
o
g
rr
a
m
m
a
T
e
m
p
o
Te
c
n
ic
o
Ins
ta
lla
z
A
c
qu
a c
a
ld
a
C
ir
c
ui
to r
is
c
a
ld
a
m
ento
I
C
ir
c
ui
to r
is
ca
lda
m
e
nto
II
P
ann
e
ll
i s
o
la
ri
4
3
2
1
1
2
1
2
1
2
Circl time
Turning the rotary knob in a clockwise
direction you can select the timer program
for display or adjustment. Refer to table.
Note: (**) If necessary personalize the
HEATING SLOPE parameter.
Outdoor temperature °C
Fl
o
w
t
e
m
pe
ra
tu
re
°
C
20
16
-16
12
-12
8
-8
4
-4
0
20,0
40,0
60,0
80,0
100,0
0,2
0,4
0,6
0,8
1
1,25
1,5
2
3
2,5
A
s
si
st
e
n
z
a
D
a
ta
/O
ra
/F
e
ri
e
V
is
u
a
liz
z
a
zi
o
n
e
Ut
e
n
te
P
ro
g
rr
a
mma
T
e
mp
o
Te
c
n
ic
o
In
s
ta
lla
z
A
c
qu
a c
a
ld
a
Ci
rc
u
it
o
ri
s
c
a
ld
a
m
e
n
to
I
C
ir
c
ui
to
r
is
cal
da
m
e
nt
o
II
P
a
nn
el
li s
o
la
ri
4
3
2
1
1
2
1
2
1
2
®
Expert
•
Open the heating controller’s panel cover and turn the ro-
tary knob in a clockwise direction until the EXPERT area
menu appears on the display.
A
ssist
e
n
z
a
Da
ta
/O
ra
/F
e
ri
e
V
is
u
al
iz
z
a
z
ion
e
Ut
e
n
te
Pr
o
g
rr
a
m
m
a
T
e
m
p
o
Te
c
n
ic
o
Ins
ta
lla
z
A
c
qu
a c
a
ld
a
C
ir
c
ui
to r
is
c
a
ld
a
m
ento
I
C
ir
c
ui
to r
is
ca
lda
m
e
nto
II
P
ann
e
ll
i s
o
la
ri
4
3
2
1
1
2
1
2
1
2
Heat circuit i
- Press the programming key to gain access
to the parameter list of the HEAT CIRCUIT I
in the EXPERT area menu.
By turning the rotary knob in a clockwise
direction you can select the parameter you
which to adjust. Refer to table below.
- Search for the HEAT CIRCUIT I level
Heat circuit I
Designation
Value range
Default
IV
MAX T-FLOW
20°C – 110° C
80 °C
MIN T-FLOW
10°C – 110°C
10 °C
FROST PROT
——;
0 °C
(-15)°C – (5)°C
OUT-TEMP-DEL
0:00 – 24:00
0:00
SLOPE OFFSET
0K – 50K
5
centigrade
B-HEAT SINK
00, 01
01 = ON
(OFF/ON)
RETURN
Exit level using
If necessary personalize the parameters MAX
T-FLOW / MIN T-FLOW / FROST PROT
Repeat the same procedure for HEAT CIRCUIT
II if present.
- When the time has elapsed the cursor
will position
itself on the INSTALLATION level.
Summary of Contents for Alkon Cargo 35
Page 1: ...ALKON CARGO 35 INSTALLATION AND SERVICING MANUAL 00332603 2nd edition 04 2008 ...