Operating instructions and part catalogue, BALE WRAPPING MACHINE, TWISTER
Page 43
SWITCHING ON/OFF BALE PRESENCE CHECKUP
Use
or
button to set the arrow marker next to the picture of
Press and hold
button until the sign changes into negative. In such case, S10 sensor status
is not taken into consideration when starting the wrapping cycle. Setting is remembered after the con-
troller power supply is turned off.
Analogically switch on the checkup of bale presence at the wrapping machine.
SWITCHING ON/OFF THE FOIL BREAK CHECKUP
Use
or
button to set the arrow marker next to the picture of
.
Press and hold
button until the sign changes into the negative. In such case, foil breakage is
not checked during wrapping the bale.
SETTING AUTOMATIC BALE EJECTION
For the safety reasons, after the controller is switched on, the program will always enter into the manu-
al ejection mode.
Use
or
buttons to set the arrow marker next to the picture of
.
Press and hold
button until the picture changes into
.
In such case, the bale will be automatically unloaded from the wrapping machine. The Automatic Ejec-
tion Setting is not remembered after the power supply is switched off.
Press and holding
button again to reconfigure back to the manual bale ejection.
SENSORS STATUS
Digits 10
– 21 correspond to status of sensors S10 – S21. In case sensor is induced (is near magnet)
sensors’ number is displayed in the negative (sensor S11 and S 20 on Fig. 34 above). That way is
possible to check functionality of all the sensors on the machine.
Summary of Contents for TWISTER
Page 57: ...Operating instructions and part catalogue BALE WRAPPING MACHINE TWISTER Page 57 10 3 Loader ...
Page 63: ...Operating instructions and part catalogue BALE WRAPPING MACHINE TWISTER Page 63 10 6 Table ...
Page 69: ...Operating instructions and part catalogue BALE WRAPPING MACHINE TWISTER Page 69 Rotating arms ...
Page 93: ...Operating instructions and part catalogue BALE WRAPPING MACHINE TWISTER Page 93 10 14 Sensors ...