![UNAOHM AP 401 Full HD User Manual Download Page 31](http://html.mh-extra.com/html/unaohm/ap-401-full-hd/ap-401-full-hd_user-manual_838174031.webp)
AP401FULL- HD_rev. 09_UK
30
4.15.2.
SPECT MENU
Hold down the
SPECT
button to access the relative menu:
4.15.2.1.
SPECTRUM GRID
Press the
ENTER
button and turn the shaft encoder to enable or disable the display of the
level reference grid upon the screen. Press
ENTER
to confirm.
4.15.2.2.
SPECTRUM SCALE
Press the
ENTER
button and turn the shaft encoder to alternate the grid’s resolution
between 5 dB and 10 dB. Press
ENTER
to confirm.
4.15.2.3.
LEVEL INDICATOR (using the level indicator)
Select this menu item to set the level indicator to BAR mode (displays an analogue
amplitude bar on the right hand side of the screen), LINE mode (displays a horizontal
amplitude line that coincides with the intersection of the frequency marker), or else OFF (to
deactivate the indicator entirely).
4.15.2.4.
HOLD FUNCTION
When this menu item is selected, the ENTER button can be pressed in order to set the
method of use:
⇒
FREEZE: freezes the screen at the moment in which the function in activated.
⇒
MIN: the minimum detected level remains on the screen
⇒
MAX: the maximum detected level remains on the screen
Press the
SPECT.
button
to exit the menu.
4.16.
DATA LOGGER
The instrument’s Data Logger allows for measurements to be performed and for the results
to be stored in the system’s memory. The stored data can then be accessed by means of
the system's display, as well as through the RS232 serial port.
For each entry, in addition to the frequency and channel, the following elements can also be
saved:
for analogue signal measurements: level, V/A, C/N.
for digital signal measurements: POW, C/N, BER, MER, NM.
Following acquisition, all of the data can be cleared simultaneously
The Data Logger’s structure allows for the acquisition of analogue and/or digital program
measurements, up to a maximum of 50 programs for each of the five acquisition plans.
If “OPT” mode is selected for the plan in use, in addition to the optical measurements, the
RF measurements deriving from the optical / RF conversion will also be saved.
Press the
DATA
button for about two seconds to enable the use of the Data Logger.
The screen will display the main menu: in order to make a selection,
turn the DIAL to
highlight the desired item and press
ENTER
.
•
DATA LOGGER:
selecting this menu item will open a window that allows for the five
available plans to be utilized:
PLAN A
PLAN B
PLAN C
PLAN D
PLAN E