A-22
Appendix A
COMMUNICATIONS
Type
Direction
of Data
(Note 1)
Character String
Sent/Receive
(Note 2)
Description Remarks
Run Status
→
MJ01CS8E\
Run Status Check
←
MJ01NS00F9\ Stop
MJ01NA00E7\ Acceleration
MJ01NB00E8\ Deceleration
MJ01NN00F4\ Normal
Rotation
MJ01FS1C05\ Failure
Stop
MJ01FF32E9\ Failure
Idle
MJ01FR15F6\
Failure Regeneration
Power failure occured
MJ01FB60E6\ Failure
Deceleration
→
MJ01CF01E2\
Read Alarm List
Confirm first alarm
←
MJ01CA011543\
Send Alarm List
Power failure occured
Parameter
→
MJ01PR03FD\
Read Parameter
Parameter 03 (rotational speed)
←
MJ01PA032700B5\
Send Parameter
Data = 2700 (27000 rpm)
Timer
→
MJ01TR01FF\
Read Timer
Timer 01 (Run time)
←
MJ01TA01001350304
0515000000000000B
9\
Send Timer
Timer 01 = 135 (135 hours)
Last update : 2003/4/5 15:00
Last reset : (invalid)
→
MJ01TC03F2\
Clear Timer
Clear timer 03 (Number of power
failure touch-downs.)
←
MJ01TA03000000304
0515000304051500C
4\
Send Timer Value
Sets timer number 03 = 0 to date/time
cleared. Sets reset date/time to date/
time when clear command was sent.
→
MJ06TW060500003\
Write Timer Value
Sets timer number 03 to 5000 (time of
maintenance call)
←
MJ01TA06050000304
0515000304051500C
C\
Send Timer Value
Sets timer number 06 = 5000 to date/
time updated and reset date/time to
date/time when write command was
sent.
履歴
→
MJ01GA01E1\
Read Alarm History
History 01
←
MJ01GB0103040112
0015NN0100001000
02750004000600030
00300050005000200
120098\
Send Alarm History
History : 01
Date & time : 2003/04/01 12:00
Alarm : power failure
Status : normal rotation
Rotational speed : 100 %
Motor current : 1.0 A
Reserved bytes : 000275
Reserved bytes : 0004
Reserved bytes : 0006
Reserved bytes : 0003
Reserved bytes : 0005
Reserved bytes : 0005
Reserved bytes : 0002
Runtime : 1200 hours
→
MJ01GA10E1\
Read Alarm History
History 10
←
MJ01GV10F6\
No History Data
Less than 10 alarm data
Summary of Contents for UTM300B
Page 8: ...vii Location of label...
Page 11: ...x This page is intentionally left blank...
Page 17: ...xvi Table of contents This page is intentionally left blank...
Page 51: ...34 SECTION 5 INSTALLATION This page is intentionally left blank...
Page 70: ...GAS PURGE 7...
Page 77: ...60 SECTION 8 TURBO MOLECULAR PUMP RECONDITION This page is intentionally left blank...
Page 111: ...A 26 Appendix A COMMUNICATIONS This page is intentionally left blank...