15
1 TECHNICAL CHARACTERISTICS
The electric diagram of the dispenser is located in the inner
part of the dispensing side panel.
Specifications are subject to change without notice.
2 INTRODUCTION
Please read all sections of this manual thoroughly to familiarize
yourself with all aspects of the unit.
Like all mechanical products, this machine will require cleaning
and maintenance. Besides, dispenser working can be
compromised by operator’s mistakes during disassembly and
cleaning. It is strongly recommended that personnel responsible
for the equipment’s daily operations, disassembly, cleaning,
sanitizing and assembly, go through these procedures in order
t o b e p r o p e r l y t r a i n e d a n d t o m a k e s u r e t h a t n o
misunderstandings exist.
3 INSTALLATION
1
Remove the corrugate container and packing materials and
keep them for possible future use.
2
Inspect the uncrated unit for any possible damage. If
damage is found, call the delivering carrier immediately to file a
claim.
3
Install the unit on a counter top that will support the
combined weight of dispenser and product
bearing in mind
what is stated in the preceding point 1 IMPORTANT
warning.
4
A minimum of 15 cm (6”) of free air space all around the unit
should be allowed to guarantee adequate ventilation.
5
Ensure that the legs are screwed tightly into the base of the
machine.
Replace the standard legs originally installed with the 100 mm
(4”) legs whenever they are provided with the unit.
6
Before plugging the unit in, check if the voltage is the same
as that indicated on the data plate. Plug the unit into a
grounded, protected single phase electrical supply according to
the applicable electrical codes and the specifications of your
machine. When the unit has no plug, install a proper grounded
plug, in compliance with electrical codes in force in your area,
suitable to at least 10 Amp 250 Volt (220-230 Volts 50-60 Hz
areas) and 20 Amp 250 Volt (100-115 Volts 50-60 Hz areas)
applications. Should you prefer to connect the unit directly to
the mains, connect the supply cord to a 2-pole wall breaker,
whose contact opening is at least 3 mm. Do not use extension
cords.
7
The unit doesn’t come presanitized from the factory. Before
serving products, the dispenser must be disassembled,
cleaned and sanitized according to this handbook instructions
(chapter 5.3 CLEANING AND SANITAZING PROCEDURES).
4 TO OPERATE SAFELY
1
Do not
operate the dispenser without reading this
operator’s manual.
2
Do not
operate the dispenser unless it is properly
grounded.
3
Do not
use extension cords to connect the dispenser.
4
Do not
operate the dispenser unless all panels are
restrained with screws.
5
Do not
obstruct air intake and discharge openings: 15 cm
(6”) minimum air space all around the dispenser.
6
Do not
put objects or fingers in panels louvers and faucet
outlet.
7
Do not
remove bowls, augers and panels for cleaning or
routine maintenance unless the dispenser is disconnected from
its power source.
5 OPERATING PROCEDURES
1
Clean and sanitize the unit according to the instructions in
IT 1P
IT 2
IT 3
Transparent removable bowls
n
1
2
3
Capacity of each bowl, approx.
l
10
10
10
Dimensions:
width
cm
28
36
54
depth
cm
47
47
47
height
cm
69
69
69
Net weight, approx.
kg
25
39
53
Gross weight, approx.
kg
28
42
56
Adjustable thermostats
n
1
2
3
Hermetic compressor
Air-cooled condenser
Overload protector
Safety pressure switch
Noise level lower than 70 dB (A)
IMPORTANT
Read electrical ratings written on the data plate of the
individual units; the data plate is adhered on the dispen-
sing side panel of the unit, just behind the drip tray (the
right side drip tray in multiple bowl models). The serial
number of the unit (preceded by the symbol #) is adhered
inside the left switch box. Data plate specifications will
always supersede the information in this manual.
IMPORTANT
When handling the machine never grasp it by the bowls
or by the evaporator cylinders. The manufacturer refuses
all responsibilities for possible damages which may
occur through incorrect handling.
ATTENTION
Failure to provide proper electrical ground according to
applicable electrical codes could result in serious shock
hazard.
IMPORTANT
Install the dispenser so that the plug is easily accessi-
ble.
ATTENTION
In case of damages, the power cord must be replaced by
qualified personnel only in order to prevent any shock
hazard.
Summary of Contents for IT GL
Page 59: ...59...