The Label-Taken Sensor Kit consists of:
• One Reflecting Sensor assy. with cable and connector
• One Sensor Bracket
• One Screw
• One Installation Instructions booklet
The only tools needed are #T10 and #T20 Torx screwdrivers and
a small non-conductive flat-tipped screwdriver.
The LTS must either be enabled by means of an
LTS& ON
statement,
or the status of the LTS has to be polled in the UBI Fingerprint
program by means of the
PRSTAT
function, as otherwise the printer
will not react on the LTS signal.
❑
Make a simple program that checks the printer's status, e.g.:
10
BREAK 1,88
20
BREAK 1 ON
30
ON BREAK 1 GOSUB 1000
40
FORMFEED
50
IF (PRSTAT AND 2) THEN BEEP
60
GOTO 50
70
END
1000 BREAK 1 OFF
1010 GOTO 70
RUN
You can break this program by transmitting the character X
(ASCII 88 decimal) on the standard serial interface "uart1:".
❑