XIIMUS 4K CL User Manual. Model: 4096CT. Version 1.4
Bit CR selects whether the shading correction unit is used or not:
0 = disable shading correction unit (default)
1 = enable use of shading correction unit.
Bit RS selects where the serial port data is routed to
0 = RS-232 port (default)
1 = Camera Link
®
Serial port
Note:
Once the serial port is routed to another location, this setting must be saved to memory bank 0 if
the same port is desired to be available on power-up.
3.10.
Shifter register (address 209)
The shifter register is associated with the Pixel Correction Unit. The setting of this register
defines which digital number is interpreted as multiplying with unity. This register setting is
meaningful only when correction is enabled.
Function decimal
hexadecimal
binary
Shifter register
209 D1
1101
0001
The data byte consists of eight bits, which are labelled as follows (MSB first):
X X X X X D2 D1 D0
D2
D1
D0
Unity level of multiplier
0 0 0
16384
0 0 1
8192
0
1
0
4096 (default value)
0 1 1
2048
1 0 0
1024
1 0 1
512
1 1 0
256
1 1 1
128
3.11.
Test modes (address 210)
This function can be used to test camera functionality with or without a grabber.
Function decimal
hexadecimal binary
Test Modes
210 D2
1101
0010
The data byte bits are defined as follows:
R1 R0 G1 G0 B1 B0 AC X
© TVI Vision, 14 July 2006 page 45 ( 56 )