XIIMUS 4K CL User Manual. Model: 4096CT. Version 1.4
Supply voltage:
Nominal:
+24
V
DC
Range:
+20 to +36 V
DC
Supply current:
Typically:
500 to 1000 mA
Maximum:
1.1 A (at +24 V
DC
and at power-up only)
Ripple:
±
10 % (max 120 Hz)
- voltage level (=n ripple) must stay
b20 to +36 V
5.2 LED
indicators
From top downwards the LEDs are as follows:
POWER, green
ON:
power input OK
RUN, green
ON: normal
operation
OFF:
¹ The higher temperature limit has been exceeded and the
camera operation has been shut down. After the external tem-
perature has fallen into the specified range, switch the power
once OFF and then ON again.
² The camera did not start up properly. Check the input power
lines and the POWER LED. The power supply must be able to
supply enough current quickly at beginning of the power-up.
STATUS 1, green
ON:
Correction unit (PCU) is enabled
OFF:
Correction unit (PCU) is disabled
STATUS 2, green
ON:
Camera is ready for operation with correction data loaded.
OFF:
Camera is performing internal boot cycle
PWR ERROR, red
ON:
at least one of the internal supply voltages has failed
© TVI Vision, 14 July 2006 page 17 ( 56 )