HIGH PO2
When partial pressure of oxygen (PO2) increases to 0.20 (ATA)
less than the PO2 Alarm value set*, the Audible will sound.
*While in Deco, High PO2 will only alarm at 1.60.
> The graphic PO2 and Up Arrow icon will be displayed
flashing on the Main (Fig. 89A) until the Audible is
silenced, then the graphic PO2 will alternate with NDC
time (Fig. 89B) until PO2 decreases 0.2 (ATA) below the
alarm Set Point.
> The value of PO2 can be viewed on ALT 2.
• S (< 2 sec) to acknowledge/silence the Audible.
• A (< 2 sec) to view ALTs.
• M (2 sec) to access the Gas Switch Routine.
• L (press) to activate Backlight.
> When PO2 reaches the Alarm Set Point, the Audible will
sound again.
> The Up Arrow icon will flash on the Main screen until PO2
decreases 0.20 (ATA) below the alarm Set Point.
Fig. 89A - HIGH PO2 MAIN
(during Audible)
Fig. 89B - HIGH PO2 MAIN
(after Audible)
alternate
w/ PO2