Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
Parameter description:
Set the characteristic of a servo drive from servo "OPERATION ENABLE" to
"READY TO SWITCH ON".
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
111
0x605C
Disable operation
option code
-
0x0000~0x0001
0x0001
Immediately
Byte0: Disable operation option code
0x00-Immediately stop the motor output, and the motor stops freely;
0x01-"Slope deceleration" decelerates to zero, and then blocks the PWM pulse.
Byte1: Reserved. The default value is 0
Parameter description:
Set the characteristic of a servo controller from servo "OPERATION ENABLE" to
"SWITCH ON".
User permission:
User/Engineer.
Parameter permission:
Read and Write
Motor Overload Parameter Setting
7.7.4
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
85
0x20A6
Motor Overload
Warning Level
%
1~100
80
Immediately
Parameter description:
This parameter is set to the percentage of the motor overload protection threshold.
When the motor load rate exceeds this threshold, the drive will report a motor overload warning.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
149
0x202D
Motor Fast
Overload Alarm
Level
%
100~500
200
Immediately
129
Summary of Contents for EtherCAT CoolDrive RC Series
Page 1: ...Updated on Update summary Updated version Version number D3 ...
Page 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Page 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Page 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Page 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...