Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective time
81
0x2094
Fault
Operation
Switch
—
0x00000000~0x01010101 0x01010100
Restart
Byte0: Fault reaction option code
0x00-"Can not reset fault" is cleared after re-power on;
0x01-"Can not reset fault " is cleared immediately;
Byte1: Detection switch for the output phase loss
0x00-Disable detection for the output phase loss
0x01-Enable detection for the output phase loss
Byte2: Drive external fault detection switch
0x00-Disable drive external fault detection;
0x01-Enable drive external fault detection.
Byte3: Detection switch for the output short circuit to ground
0x00-Disable detection for the output short circuit to ground
0x01-Enable detection for the output short circuit to ground
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
78
0x2090
Slow Ramp
Deceleration
inc/ms²
1~3000
30
Immediately
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
79
0x2092
Active Stop
Delay Time
ms
100~10000
500
Immediately
127
Summary of Contents for EtherCAT CoolDrive RC Series
Page 1: ...Updated on Update summary Updated version Version number D3 ...
Page 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Page 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Page 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Page 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...