U243
Checking the operation of the DP motors
Description
Turns the motors or solenoids in the DP on.
Purpose
To check the operation of the DP motors and solenoids.
Method
1. Press the start key.
2. Select the item to be operated.
3. Press the start key. The operation starts.
*1
: DP-770(B)
*2
:
DP-772
*3
: DP-773
4. To turn each motor off, press the stop key.
Completion
Press the stop key when operation stops. The screen for selecting a maintenance item No. is dis-
played.
Item No.
Description
Display
Description
Feed Motor
*1,*2,*3
DP original feed motor (DPOFM) is turned on
Conv Motor
*1,*2
DP original conveying motor (DPOCM) is turned on
Rev Motor
*1,*3
DP switchback motor (DPSBM) is turned on
Lift Motor
*1,*2
DP lift motor (DPLM) is turned on
Rev Press Sol
*1
DP pressure solenoid (DPPSOL) is turned on
Rev Branch Sol
*1
DP feedshift solenoid (DPFSSOL) is turned on
Eject Motor
*2
DP eject motor (DPEM) is turned on
Regist Motor
*2
DP registration motor (DPRM) is turned on
DP Fan
*2
DP fan motor 1 (DPFM1) is turned on
CIS Fan
*2
DP fan motor 2 (DPFM2) is turned on
Summary of Contents for DP 773
Page 1: ...Service Manual Document Processor DP 773 First Edition Date 30 08 2013 3PHSM060 ...
Page 3: ...Revision history Revision Date Replaced pages Remarks ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 16: ...3PC 1 1 4 This page is intentionally left blank ...
Page 20: ...3PH 1 2 4 This page is intentionally left blank ...
Page 91: ...3PH 1 5 14 This page is intentionally left blank ...
Page 93: ...3PC 1 6 2 This page is intentionally left blank ...
Page 105: ...3PH 2 2 5 This page is intentionally left blank ...
Page 109: ...3PH 2 3 4 This page is intentionally left blank ...