11
CHAPTER
3
CHAPTER 3 - UNIT PREPARATIONS
3.1. Handling Instructions
The PRESTIGE Solo is generally easier to handle and
maneuver once removed from the shipping carton.
To remove the shipping carton:
Use care not to drop, bump or rotate the boiler
upside down, as damage to the boiler will result.
1. Remove any shipping straps and open the side of
the shipping carton.
2. Slide the unit with the foam inserts out of the carton.
3. Discard all packing materials.
3.2. Wall Mounting Installation
The PRESTIGE Solo should be wall mounted using the
bracket provided with the boiler. The PRESTIGE Solo is
not designed for floor installation. If floor installation is
required, an optional floor stand is available through Tri-
angle Tube. The PRESTIGE Solo is not to be installed on
carpeting
The wall used for mounting the PRESTIGE
Solo must be vertically plumb and capable of
supporting a minimum 130 pounds [59 kg]
for the PRESTIGE Solo 80/110, 175 pounds [80
kg] for PRESTIGE Solo 155/175/250 and 265
pounds [120 Kg] for PRESTIGE Solo 299/399.
Failure to comply with these requirements
can result in substantial property damage,
serious injury, or death.
NOTICE
WARNING
3.3. Wall Mounting Guidelines
The wall-mounting bracket is designed for stud spac-
ing of 12 inch or 16 inch on centers. For unconvention-
al stud spacing, a solid / secure mounting surface must
be provided for installation of the bracket.
1. For applications using wood studs, install the brack-
et using the lag screws provided with the boiler.
Ensure both lag screws are installed securely in the
studs.
2. For applications using metal studs, install the brack-
et to the studs using 3/16” toggle bolts and wash-
ers.
3. DO NOT mount or attempt to mount the wall
bracket to hollow sheet rock or lath walls using
anchors. Only install boiler to studs or equivalent
wood structure.
4. For applications using solid walls (rock, concrete,
brick, cinder block, etc.), install the wall bracket us-
ing anchors (double expansion shields) and bolts
with washers provided with the boiler.
5. The boiler is too heavy and bulky for a single person
to lift and attempt to mount; a minimum of 2 peo-
ple are required for mounting the boiler.
Use extreme care not to drop the boiler or
cause bodily injury while lifting or mount-
ing the boiler onto the wall bracket. Once
mounted, verify that the boiler is securely
attached to the bracket and wall. Failure to
comply with the above guidelines can result
in substantial property damage, serious inju-
ry, or death.
WARNING
Summary of Contents for PRESTIGE Solo PA 110
Page 2: ...INTENTIONALLY LEFT BLANK...
Page 10: ...INTENTIONALLY LEFT BLANK...
Page 22: ...INTENTIONALLY LEFT BLANK...
Page 36: ...INTENTIONALLY LEFT BLANK...
Page 44: ...INTENTIONALLY LEFT BLANK...
Page 52: ...INTENTIONALLY LEFT BLANK...
Page 74: ...INTENTIONALLY LEFT BLANK...
Page 76: ...INTENTIONALLY LEFT BLANK...
Page 80: ...INTENTIONALLY LEFT BLANK...
Page 82: ...INTENTIONALLY LEFT BLANK...
Page 84: ...INTENTIONALLY LEFT BLANK...
Page 111: ......