ENTRY MODES
VALIDATION
LOCATION
1
or
2
70
#
USER PIN ENTRY MODE – Auto or Manual (Location 70)
USER PIN ENTRY MODES
Two modes 1 and 2 are available for User PIN entry options. The EM Card is always in Auto Entry Mode and is not
affected by the selection here.
1
--- Auto Entry Mode
Auto Entry Mode requires no pressing of the
#
key following the User PIN for code checking.
In the Auto Entry Mode, the
User PINs MUST be set in the same digit length of the Master Code
(For example, if
the Master Code is 5 digits, then all User PINs must be in 5 digits as well. All other User PINs not in 5 digits become
invalid). When the number of digits reaches, the system will check the User PIN automatically. Good for high traffic
access control.
2
--- Manual Entry Mode – (Default)
Manual Entry Mode always requires the
#
key following of the User PIN for code checking. The User PINs can be
4-8
digits arbitrary
and they are
NOT
required to be in the same digit length of the Master Code. Manual Entry increases
the level of security in the code trial by the unauthorized people.
PACIFIER TONES ON-OFF SELECTION (Location 71)
PACIFIER TONES ON-OFF MODES
The Pacifier Tone is the Beep Tones from the keypad, which include the tones of Successful Key entry (1 beep), the
Output Operation Announcer (2 beeps or 1 long beep) and the Unsuccessful User Code/Card entry (5 beeps).
NOTE :
The beeps for the Warning and the Power-up Delay do not belong to pacifier tones and can not be set to OFF.
1
--- Pacifier Tone ON – (Default)
All the Pacifier Tones available from the keypad are enabled. They are the response tones indicating the operation
status of the keypad after the Card/User Code is entered.
0
--- Pacifier Tone OFF
All the Pacifier Tones are OFF. Good for place needs for a silent environment.
OUTPUT OPERATION ANNOUNCER (Location 72)
OUTPUT OPERATION ANNOUNCER
The announcer gives notification beep to the users and the visitors on the operation status of the outputs. There are
two notification modes available for the selection.The notification is also OFF while the Pacifier Tone OFF mode in the
Location 71 is selected.
1
--- 1 Second Long Notification -- (Default)
1 second notification beep is given when the output relay is activated with a valid Card/Code or Egress Button.
It is prepared to notify the person outside the door when the lock is released and the door can be opened. It is good
for the door lock device gives no sound when it activates, such as a magnetic lock.
0
--- 2 Short Beeps Notification
2 short beeps notification is given when the output is activated with a valid Code.
FUNCTION MODES
VALIDATION
LOCATION
FUNCTION MODES
VALIDATION
LOCATION
1
or
0
1
or
0
#
#
71
72