CONFIGURATION OF THE OUTPUT MODES OF OUTPUT 1, 2 AND 3 (Locations 51, 52 & 53)
The three relay outputs of this keypad are programmable for Start/Stop or Timing modes. Apart from the door access
control, alarm arm-disarm control, they are also
universal timers for automatic operators in industry
with their
99,999 seconds (over 24 hours) programmable timer.
OUTPUT LOCATIONS
51
-- Location for Output 1
52
-- Location for Output 2
53
-- Location for Output 3
OUTPUT MODE & TIMING
0
– Start /Stop Mode (Toggle)
The number 0 sets the output to the
Start / Stop mode
. The output
Starts
when an User PIN and/or Card is
entered/read; the output
Stops
when an User PIN and/or Card is entered/read again.
1
-
99999
Seconds Momentary --- (Default -- Momentary 5 Seconds)
The output can be set in
Momentary Mode
with the time of 1 second to 99,999 seconds. The output will reset
automatically when the time expires OR it can be
RESET manually at anytime with the Super User Code
that
operates the desired output before the end of the time.
Example :
Reset Output 1 --
#
1
------------- Output 1 resets
Reset Output 2 --
#
2
------------- Output 2 resets
Reset Output 3 --
#
3
------------- Output 3 resets
PERSONAL SAFETY AND SYSTEM LOCK-OUT (Location 60)
SAFETY & LOCK-OUT OPTIONS
The Options are represented by their Mode Numbers in programming. They are described below:
1
--- After 10 successive false Card/User Code trials, the keypad locks during 60 seconds. -- (Default)
2
--- After 10 successive false Card/User Code trials, activates the Duress output to switch to ( -) ground.
The Duress Output can be released with any user PIN or Card in the User Group 1 or the Super User PIN.
5
-
10
---Selection of after 5 to 10 successive Card/User Code trials, the keypad locks during 15 minutes.
The keypad can be reset to release the lock-out with the “Super User Code” in the following way.
Example :
Release the lock-out --
#
9
00
--- Disappearance of all the above lock-out securities.
SUPER USER CODE
SUPER USER CODE
SUPER USER CODE
1 to 2 Digits
LOCK-OUT MODES
VALIDATION
LOCATION
60
#
SUPER USER CODE
OUTPUT MODE & TIME
VALIDATION
LOCATIONS
51
-
53
0
or
1
-
99999
#
23
a) Put the EM card close to the reader. One-beep confirms the reading and 30 seconds waiting time is given for the
entry of the Duress Code, the Amber LED keeps flashing.
b) Key in the Duress Codes 3 3 6 9 for operating the Output 1
c) Confirm it with the # key. Output 1 activates in a normal