REFRESH THE SYSTEM WITH THE “REFRESHING CODE” --- 9 9 9 9
The system can be refreshed to clear all the old data stored and back to its ex-factory default values.
IMPORTANT NOTE:
Make sure that you really want to clear
ALL the OLD
data before entering of the Refreshing Code. The keypad will be
back with its default values like a new unit. Re-program of the desired values are necessary.
REFRESHING CODE
The Code
9 9 9 9
is for refreshing of the system. Once it is keyed in and validated with #, all the values
programmed previously will be cleared
EXCEPT the Master Code
.
The refreshing takes around 2.5 minutes. During the keypad is being refreshed the Status LED (Amber) flashes
fast until the end.
THE DEFAULT VALUES OF THE KEYPAD
PROGRAMMING
LOCATION
PARAMETERS
DEFAULT FUNCTIONS & VALUES
0 1
Master Code
0 0 0 0 Factory Set, Not a default value *
0 2
Super User PINs
Nil ----- User Program Required
1 0
User PINs & Cards for O/P 1
Nil ----- User Program Required
2 0
User PINs & Cards for O/P 2
Nil ----- User Program Required
3 0
User PINs & Cards for O/P 3
Nil ----- User Program Required
03
Common User PIN 1
Nil ----- User Program Required
04
Common User PIN 2
Nil ----- User Program Required
05
Common User PIN 3
Nil ----- User Program Required
4 0
Visitor Codes
Nil ----- User Program Required
4 1
Duress Code for O/P 1
Nil ----- User Program Required
4 2
Duress Code for O/P 2
Nil ----- User Program Required
4 3
Duress Code for O/P 3
Nil ----- User Program Required
5 1
O/P Mode of The O/P 1
Time = 5 Sec, Momentary
5 2
O/P Mode of The O/P 2
Time = 5 Sec, Momentary
5 3
O/P Mode of The O/P 3
Time = 5 Sec, Momentary
6 0
Personal Safety & Lock-out
Code = 1, 10 False Code Lock-out 60 Sec
7 0
User Code Entry Mode
Code = 2, Manual Entry Mode
7 1
Pacifier Tones ON-OFF Selection
Code = 1, Pacifier Tone ON
7 2
O/P Operation Announcer
Code = 1 Sec, Notification Beep ON
7 3
Status LED Standby Flashing ON-OFF
Code = 1, Flashing Enabled
8 0
Door Forced Open Warning & Timing
Code = 0, Warning Disabled
8 1
Door Propped-up Warning & Delay
Code = 0, Warning Disabled
9 0
Egress Delay & Warning
Code 1 = 0, Instant, No Delay
Code 2 = 1, Momentary Contact without Warning
9 1
Door Opening Alarm & Timer
Code = 0, Alarm O/P Disabled
9 4
Operation Modes & Wiegand Output
Code = 0, Wiegand O/P for Valid Code Only
NOTE:
The DAP Code
8 0 8 0
and the Refreshing Code
9 9 9 9
are fixed in the operating system program. It can not be
changed in any ways or be influenced by the system in default setting.
REFRESHING CODE
VALIDATION
9999
#
11