2) BASIC WIRINGS OF A STAND ALONE DOOR LOCK WITH INHIBIT AUTHORIZATION CODE
Use output 3 as authorization control. The owner may key in the user code 3 to stop the operation of the electric
lock in the night time or after office hour to prevent unauthorized access.
Set output 3 in Start / Stop mode (Programming Location 53 Output Mode =0) for ON-OFF control.
Simply connect the "output 1 inhibit" (O/P 1 INHIB) terminal with output 3 as like the wiring diagram shown. User
code 1 is invalid while the "O/P 1 INHIB" terminal is shunted to ground with user code 3.
NOTE:
1) The Inhibit Authorization Control in this example is made up with hardware connection of Output 3 to the “Output
1 Inhibit” terminal. It gives inhibit function to all User PINs and Cards and the Egress Button for Output 1 with the User
PIN 3.
2) A software Inhibit function is also available in the keypad. It is made up with the .
The Inhibit function in this way gives to all User PINs for Output 1 only but not to the Egress Button. Please see
Location 02 for the details.