SPECIFICATIONS
Operating Voltage:
12V-24V DC, Auto adjusting
Operating Current:
75mA (quiescent) to 145mA (three relays active)
Operation Temperature:
-4 F to 158 F
Environmental Humidity:
5-95% relative humidity non-condensing
Working Environment & Ingress Protection:
All weather, IP-66
Number of Users:
Output 1 – 1,000 User PINs and/or Cards + 50 Duress Codes
Output 2 – 100 User PINs and/or Cards + 10 Duress Codes
Output 3 – 100 User PINs and/or Cards + 10 Duress Codes
Number of Visitor Codes:
50, programmable for one time or with the time limit
Timings for Code Entry:
10 seconds waiting for next digit entry
30 seconds waiting for code entry after card reading
The Timers:
Three 1-99,999 Seconds (Over 24 Hours possible) Independent Programmable Timers for O/P 1, 2 & 3
Egress Button:
Programmable for Instant, Delay with Warning and/or Alarm
Momentary or Holding Contact for the Exit Delay
Input Sensing Terminals:
a)
Door position,
b)
Egress,
c)
O/P 1 inhibit
Output Control Terminals:
Transistor Open Collector 24VDC/100mA sink Max for the following outputs
a)
Duress,
b)
Alarm,
c)
Key Active,
d)
Output 3 (Door Bell version only),
e)
Inter-lock
Output Contact Ratings:
Output Relay 1 – N.C. & N.O. dry contacts, 5A/24VDC Max.
Output Relay 2 – N.C. & N.O. dry contacts, 1A/24VDC Max.
Output Relay 3 – N.C. & N.O. dry contacts, 1A/24VDC Max. (N.O. contact only for Door Bell version)
Tamper Switch – N.C. dry contact, 50mA/24VDC Max.
Dimensions:
DOLXP1KB – 156(H) X 103(W) X 50/70(D)mm
Weight:
DOLXP1KB – 1.03Kg net
Housing:
DOLXP1KB – Anodized steel, powder paint coating outer box & plastic inner box
Faceplate Material:
.05 inches stainless steel
Specifications are subject to change for modification without notice
Proximity Card:
Standard EM Card or Keyfob, 125 KHz
5