FEATURE PROGRAMMING & OPERATION INSTRUCTIONS
SET SYSTEM INTO PROGRAMMING MODE WITH THE MASTER CODE
IMPORTANT NOTE:
1)
DO NOT TURN OFF POWER
while the keypad is in Programming Mode. Otherwise, it may cause data lost/error to the
programmed features in the memory.
2) The keypad beeps after power up. Wait 1 minute until the end of the power up delay, then key in the Master Code for
setting the system into programming mode.
3) For the owner’s convenience in programming at the first time, the factory has put a Master Code
0 0 0 0
into the
keypad (
It is NOT a default code
). To compromise security, in all cases, the owner should program a new Personal
Master Code to invalidate the factory set Master Code after the keypad is owned.
4) The
Button
has two functions in the keypads with Door Bell button. It is a door bell button while the keypad is in
normal operation; and it is equivalent to a
*
Button
in programming mode.
MASTER CODE
The Master Code can be a factory set master code or the
private master code that was set by the owner.
Validate the master code with
* *
(or ) .
2-beep confirms a valid master code. The Mains LED (Amber) is constantly
ON after the system is set in the programming mode.
DIRECT ACCESS TO PROGRAMMING MODE WITH THE “DAP” CODE – 8 0 8 0
Set System Into Programming Mode With DAP Code In Case Of The Master Code Is Forgotten ! !
The owner requires to apply the following procedures precisely to set the system into programming
mode with the DAP code
8 0 8 0.
1) Switch OFF all the power for 1 minute to ensure that the system is fully discharged.
2) Swich ON power again. The system is in Power-up Mode for 1 minute and the buzzer gives beeps during the whole
period. This is the only time limit for setting the system to Direct Access to Programming (DAP).
3) Press the Egress Button (EG IN) once first to enable the DAP function.
4) Key in the DAP Code
8 0 8 0
and validate it with
* *
(or ),
the existing Master Code in the memory is
erased
and the power up beep stops. The keypad turns itself into programming mode like using the Master Code
and it is ready to accept the new programming data.
5) If the Egress Button is not pressed and the DAP code is not keyed in within the power up period, the system will set
itself to normal operation mode. To set it back to power-up mode, repeat procedures 1-4.
DAP CODE
The DAP code is fixed on
8 0 8 0
and it is valid only in the Power-up Period after the Egress Button is pressed.
Validate the DAP code with the
* *
(or )
.
2-beep confirms the system is in the Programming Mode; and the Mains LED is constantly ON.
See “RECORD A MASTER CODE” at “Location 01” for the details of programming a new master code.
NOTE:
If the keypad is linking up with your controller in the Split-decoded operation, it is necessary to put the controller’s
“Link-up Jumper” to “ON” position to get the new Master Code for it. As the Master Code is also the link-up code of
the two units.
Do Not Forget
to put the Link-up jumper back to OFF position after the programming. Otherwise, the
controller will accept other keypads to link up with it.
0000
**
**
MASTER CODE
VALIDATION
8080
DAP CODE
VALIDATION
.
.
.
.
.
.
.
10
EGRESS BUTTON
PRESS ONCE