007
LCP copy
Value:
No
copying
(NO
COPY)
[0]
Upload all parameters (UPL. ALL PAR.)
[1]
Download all parameters (DWNL. ALL PAR.)
[2]
Download size-independent parameters
(DWNL.OUTPIND.PAR.)
[3]
Function:
Parameter 007
LCP copy
is used if you want to use the
LCP 2 control panel's integral copy function. The
function is used if you want to copy all parameter
setups from one adjustable frequency drive to anoth-
er by moving the LCP 2 control panel.
Description of choice:
Select
Upload all parameters
[1] if you want all param-
eter values to be transferred to the control panel.
Select
Download all parameters
[2] if all parameter val-
ues transferred are to be copied to the adjustable
frequency drive to which the control panel is attach-
ed. Select
Download size-independent par.
[3] if you
only want to downloade the size-independent param-
eters. This is used when downloading to a adjustable
frequency drive with a different rated power size than
that from which the parameter setup originates.
NOTE:
Upload/download can only be performed in stop
mode. Download can only be performed to a adjust-
able frequency drive with the same software version
number, see parameter 626
Database identification no.
008
Display scaling of output frequency
Value:
0.01 - 100.00
1.00
Function:
In this parameter, the factor is selected by which the
output frequency is to be multiplied. The value is
shown in the display, provided parameters 009-012
Display readout
have been set to
Output frequency x
scaling
[5].
Description of choice:
Set the required scaling factor.
009
Large display readout
Value:
No
readout
(none)
[0]
Resulting reference [%]
(reference
[%])
[1]
Resulting reference [unit]
(reference
[unit])
[2]
Feedback [unit] (feedback [unit])
[3]
Frequency [Hz] (Frequency [Hz])
[4]
Output frequency x scaling
(frequency
x
scale)
[5]
Motor current [A] (Motor current [A])
[6]
Torque [%] (Torque [%])
[7]
Power [kW] (Power [kW])
[8]
Power [HP] (Power [HP][US])
[9]
Motor voltage [V]
(Motor
voltage
[V])
[11]
DC link voltage [V]
(DC
link
voltage
[V])
[12]
Thermal load motor [%]
(Motor
thermal
[%])
[13]
Thermal load [%]
(FC.
thermal[%])
[14]
Running hours [Hours]
(RUNNING
HOURS])
[15]
Digital input [Bin]
(Digital
input[bin])
[16]
Analog input 53 [V]
(analog
input
53
[V])
[17]
Analog input 60 [mA]
(analog
input
60
[mA])
[19]
Pulse reference [Hz]
(Pulse
ref.
[Hz])
[20]
External reference [%]
(external
ref.
[%])
[21]
Status word [Hex] (Status word [hex])
[22]
Heatsink temperature [
°
C]
(Heatsink
temp
[°C])
[25]
Alarm word [Hex] (Alarm word [hex])
[26]
Control word [Hex] (Control word [Hex])
[27]
Warning word [Hex]
(warning
word
[Hex])
[28]
Extended status word [Hex]
(Ext.
status
[hex])
[29]
Communication option card warning
(COMM OPT WARN [HEX])
[30]
Pulse count
(PULSE
COUNTER)
[31]
Function:
In this parameter you can select the data value that
you wish to display in the LCP control unit display line
2 when the frequency converter is switched on. The
display will also be included in the scrollbar in display
mode. In parameters 010-012
Display readout
you can
select a further three data values, which are displayed
in display line 1.
Description of choice:
No readout
can only be selected in parameters
010-012
Small display readout
.
Resulting reference [%]
gives, as a percentage, the re-
sulting reference in the range from Minimum refer-
ence, Ref MIN to Maximum reference, Ref MAX.
Reference [unit]
gives the resulting reference with unit
Hz in
Open loop
. In
Closed loop
the reference unit is
selected in parameter 416
Process units
.
TR1
2800
Series
VFD
19
Programming
Summary of Contents for VarioTrane TR1 2800 Series
Page 2: ...T TR R1 1 2 28 80 00 0 S Se er ri ie es s V VF FD D 1 1...
Page 3: ...2 2 T TR R1 1 2 28 80 00 0 S Se er ri ie es s V VF FD D...
Page 4: ...TR1 2800 Series VFD 3...
Page 7: ...6 TR1 2800 Series VFD...
Page 87: ...Illustration 5 7 192H4719 Illustration 5 8 192H4720 86 TR1 2800 Series VFD...
Page 95: ...Branch Circuit Protection Short circuit protection 94 TR1 2800 Series VFD...
Page 107: ...All about TR1 2800 Series VFD 106 TR1 2800 Series VFD...