6
6
1
1
7
7
F
F
a
a
u
u
l
l
t
t
l
l
o
o
g
g
:
:
V
V
a
a
l
l
u
u
e
e
Value:
Value:
[Index 1 - 10] Value: 0 - 9999
[Index 1 - 10] Value: 0 - 9999
Function:
Function:
In this parameter it is possible to see at which value
In this parameter it is possible to see at which value
a trip occurred. The unit of the value depends on
a trip occurred. The unit of the value depends on
which alarm is active in parameter 615
which alarm is active in parameter 615
Fault log: Fault
Fault log: Fault
code
code
..
Description of choice:
Description of choice:
Read out as one value.
Read out as one value.
6
6
1
1
8
8
R
R
e
e
s
s
e
e
t
t
o
o
f
f
k
k
W
W
h
h
c
c
o
o
u
u
n
n
t
t
e
e
r
r
Value:
Value:
N
No
o rre
es
se
et
t ((D
DO
O N
NO
OT
T R
RE
ES
SE
ET
T))
[[0
0]]
R
Re
es
se
et
t
((R
RE
ES
SE
ET
T
C
CO
OU
UN
NT
TE
ER
R))
[[1
1]]
Function:
Function:
Resetting parameter 602
Resetting parameter 602
kWh counter
kWh counter
to zero.
to zero.
Description of choice:
Description of choice:
If
If
Reset
Reset
[1]is selected and you press the [OK] key,
[1]is selected and you press the [OK] key, the
the
frequency converter's kWh counter is reset to zero.
frequency converter's kWh counter is reset to zero.
This parameter cannot be selected via serial commu-
This parameter cannot be selected via serial commu-
nication.
nication.
NOTE:
NOTE:
When the [OK] key is activated, the counter is reset to
When the [OK] key is activated, the counter is reset to
zero.
zero.
6
6
1
1
9
9
R
R
E
E
S
S
E
E
T
T
R
R
U
U
N
N
N
N
I
I
N
N
G
G
H
H
O
O
U
U
R
R
S
S
C
C
O
O
U
U
N
N
T
T
E
E
R
R
Value:
Value:
N
No
o rre
es
se
et
t ((D
DO
O N
NO
OT
T R
RE
ES
SE
ET
T))
[[0
0]]
R
Re
es
se
et
t
((R
RE
ES
SE
ET
T
C
CO
OU
UN
NT
TE
ER
R))
[[1
1]]
Function:
Function:
Resetting of parameter 601
Resetting of parameter 601
Hours run
Hours run
to zero.
to zero.
Description of choice:
Description of choice:
If
If
Reset
Reset
[1] is selected and you
[1] is selected and you press the [OK] key, the
press the [OK] key, the
frequency converter's parameter 601 is reset to zero
frequency converter's parameter 601 is reset to zero
Hours run
Hours run
. This parameter cannot be selected via se-
. This parameter cannot be selected via se-
rial communication.
rial communication.
NOTE:
NOTE:
When the [OK] key is activated, the counter is reset to
When the [OK] key is activated, the counter is reset to
zero.
zero.
6
6
2
2
0
0
O
O
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
M
M
o
o
d
d
e
e
Value:
Value:
No
Norm
rmal
al op
oper
erat
atio
ion
n (N
(NOR
ORMA
MAL
L OP
OPER
ERAT
ATIO
ION)
N)
[0
[0]]
Co
Cont
ntrrol
ol ca
card
rd te
test
st (C
(CON
ONTR
TROL
OL CA
CARD
RD TE
TEST
ST))
[[2]
2]
IIn
niittiia
alliis
se
e
((IIN
NIIT
TIIA
AL
LIIZ
ZE
E))
[[3
3]]
Function:
Function:
NOTE:
NOTE:
Please note, that the control card will be different on
Please note, that the control card will be different on
DeviceNet units. See the DeviceNet manual MG.
DeviceNet units. See the DeviceNet manual MG.
90.BX.YY for further details.
90.BX.YY for further details.
In addition to its normal function, this parameter can
In addition to its normal function, this parameter can
be used to test the control card.
be used to test the control card.
There is also the opportunity to perform an initialisa-
There is also the opportunity to perform an initialisa-
tion at the factory setting for all parameters in all
tion at the factory setting for all parameters in all
Setups, with the exception of parameters 500
Setups, with the exception of parameters 500
Ad-
Ad-
dress
dress
, 501
, 501
Baudrate
Baudrate
, 600-605
, 600-605
Operating data
Operating data
and
and
615-617
615-617
Fault log
Fault log
..
Description of choice:
Description of choice:
Normal function [0] is used for normal operation of
Normal function [0] is used for normal operation of
the motor.
the motor.
Control card test [2] is selected if you wish to check
Control card test [2] is selected if you wish to check
the control card's analog/digital inputs, analog/digital
the control card's analog/digital inputs, analog/digital
outputs, relay outputs and 10 V and 24 V voltages.
outputs, relay outputs and 10 V and 24 V voltages.
The test is performed as follows:
The test is performed as follows:
27 - 29 - 33 - 46 are c
27 - 29 - 33 - 46 are connected.
onnected.
50 - 53 are connected.
50 - 53 are connected.
42 - 60 are connected.
42 - 60 are connected.
12 - relay terminal 01 is connected.
12 - relay terminal 01 is connected.
18 - relay terminal 02 is connected.
18 - relay terminal 02 is connected.
19 - relay terminal 03 is connected.
19 - relay terminal 03 is connected.
Use the following procedure for the
Use the following procedure for the control card test:
control card test:
1.
1.
Se
Sele
lect
ct co
cont
ntro
rol
l ca
card
rd te
test
st..
2.
2.
Dis
Discon
connec
nect the
t the mai
mains vo
ns volta
ltage an
ge and wai
d wait unt
t until th
il the
e
light in the display has disappeared.
light in the display has disappeared.
3.
3.
Mou
Mount ac
nt accor
cordin
ding to dr
g to drawi
awing an
ng and des
d descri
cripti
ption.
on.
4.
4.
Co
Conn
nnec
ect t
t the
he ma
main
ins v
s vol
olta
tage
ge..
5.
5.
The f
The freq
requen
uency con
cy conver
verter a
ter auto
utomat
matical
ically un
ly under
der--
takes a test of the control card.
takes a test of the control card.
If the frequency converter displays a fault code from
If the frequency converter displays a fault code from
37-45, the control card test has failed. Change the
37-45, the control card test has failed. Change the
control card to start up the
control card to start up the frequency converter.
frequency converter.
If the frequency converter comes into Display mode,
If the frequency converter comes into Display mode,
the test is OK. Remove the test connector and the fre-
the test is OK. Remove the test connector and the fre-
quency converter is ready for operation. Parameter
quency converter is ready for operation. Parameter
620
620
Operating mode
Operating mode
is automatically set to
is automatically set to
Normal op-
Normal op-
eration
eration
[0].
[0].
Initialisation
Initialisation
[3] is selected if you wish to use the unit's
[3] is selected if you wish to use the unit's
factory setting.
factory setting.
Procedure for initialisation:
Procedure for initialisation:
1.
1.
Select
Select
Initialisation
Initialisation
[3].
[3].
2.
2.
Dis
Discon
connec
nect the
t the mai
mains vo
ns volta
ltage an
ge and wai
d wait unt
t until th
il the
e
light in the display has disappeared.
light in the display has disappeared.
3.
3.
Co
Conn
nnec
ect t
t the
he ma
main
ins v
s vol
olta
tage
ge..
4.
4.
An in
An initi
itiali
alisat
sation i
ion is perf
s perform
ormed in al
ed in all para
l paramet
meters in
ers in
all Setups, with the exception of parameters 500
all Setups, with the exception of parameters 500
Address
Address
, 501
, 501
Baudrate
Baudrate
, 600-605
, 600-605
Operating data
Operating data
and
and
615-617
615-617
Fault log
Fault log
..
8
80
0
T
TR
R1
1
2
28
80
00
0
S
Se
erriie
es
s
V
VF
FD
D
Programming
Programming
Summary of Contents for VarioTrane TR1 2800 Series
Page 2: ...T TR R1 1 2 28 80 00 0 S Se er ri ie es s V VF FD D 1 1...
Page 3: ...2 2 T TR R1 1 2 28 80 00 0 S Se er ri ie es s V VF FD D...
Page 4: ...TR1 2800 Series VFD 3...
Page 7: ...6 TR1 2800 Series VFD...
Page 87: ...Illustration 5 7 192H4719 Illustration 5 8 192H4720 86 TR1 2800 Series VFD...
Page 95: ...Branch Circuit Protection Short circuit protection 94 TR1 2800 Series VFD...
Page 107: ...All about TR1 2800 Series VFD 106 TR1 2800 Series VFD...